GHP 10 Marine Autopilot System Installation Instructions
Advanced Configuration Power-on Procedure
Advanced configuration options are not available on the GHC 10 under normal conditions. To access the advanced configuration
settings of the GHP 10, use the advanced configuration power-on procedure.
To access the wizards and advanced configuration options:
1. With the power off, press both the center and the right soft keys on the GHC 10.
2. While pressing the center and the right soft keys, power the GHC 10 on.
3. Press all 3 buttons until the heading screen appears. Release the buttons.
To make sure the wizards and advanced configuration options are available:
1. From the heading screen, select
Menu
>
Setup
.
2. If the option for
Dealer Autopilot Configuration
is available, you correctly performed the
advanced configuration power-on procedure.
Manually Running the Dockside and Sea trial Wizards
The Dockside Wizard and the Sea Trial Wizard allow you to quickly define all of the important configuration settings on the GHP 10.
If, after running the wizards, you do not feel as though the GHP 10 is working correctly, you can run the wizards again at any time. To
access the wizards, power the GHC 10 on using the advanced configuration power-on procedure.
to manually run the Dockside Wizard:
1. From the Heading screen, select
Menu
>
Setup
>
Dealer Autopilot Configuration
>
Wizards
>
Dockside Wizard
.
2. Perform the steps as prompted. For more information, see
to manually run the Sea trial Wizard:
1. From the Heading screen, select
Menu
>
Setup
>
Dealer Autopilot Configuration
>
Wizards
>
Sea trial Wizard
.
2. Perform the steps as prompted. For more information, see
Changing Advanced Configuration Settings
You can run the Autotune automated configuration process, calibrate the compass, and define north on the GHP 10 through the
GHC 10 without running the wizards. Additionally, without running the wizards, you can individually define each configuration
setting. To access the automated configuration settings and the advanced configuration settings, power the GHC 10 on using the
advanced configuration power-on procedure
To manually run the automated configuration settings:
1. From the Heading screen, select
Menu
>
Setup
>
Dealer Autopilot Configuration
>
Automated Setup
.
2. Select
Autotune
,
Calibrate Compass
, or
Set north
.
3. Perform the steps as prompted. For more information on each automated configuration setting, see
To manually define individual configuration settings:
1. From the Heading screen, select
Menu
>
Setup
>
Dealer Autopilot Configuration
.
2. Select the appropriate category of setting you want to configure.
3. Select the setting you want to configure. Refer to the description of each setting on
.
Advanced Configuration
Power-on Procedure
Hold these
soft keys
and power the
GHC 10 on
Advanced Configuration
Power-on Procedure
Hold these
soft keys
and power the
GHC 10 on