Page B-4
GDL 88 TSO Installation Manual
Rev. A
190-01122-00
B.1.5 Shadin Fuel/Air Data Computer
The GDL 88 is capable of receiving the following message strings from the Shadin Fuel/Air Data or Air
Data Computer:
SHADIN “z” FORMAT
<STX>
ZA012<CR><LF>
"ZA" (ASCII characters); "012" represents indicated Air Speed (knots)
ZB345<CR><LF>
"ZB" (ASCII characters); "345" represents true Air Speed (knots)
ZC678<CR><LF>
"ZC" (ASCII characters); "678" represents Mach Speed (thousandths)
ZD<+/->9012<CR><LF> "ZD" (ASCII characters); sign; "9012" represents pressure altitude (tens of
feet)
ZE<+/->3456<CR><LF>
"ZE" (ASCII characters); sign; "3456" represents density altitude (tens of feet)
ZF<+/->78<CR><LF>
"ZF" (ASCII characters); sign; "78" represents outside air temperature
(Celsius)
ZG<+/->90<CR><LF>
"ZG" (ASCII characters); sign; "90" represents true air temperature (Celsius)
ZH123<CR><LF>
"ZH" (ASCII characters); "123" represents wind direction (degrees from north)
ZI456<CR><LF>
"ZI" (ASCII characters); "456" represents wind speed (knots)
ZJ<+/->78<CR><LF>
"ZJ" (ASCII characters); sign; "78" represents rate of turn (degrees per second)
ZK<+/->901<CR><LF>
"ZK" (ASCII characters); sign; "901" represents vertical speed (tens of
ft/minute)
ZL234<CR><LF>
"ZL" (ASCII characters); "234" represents heading (degrees from north)
ZM5678<CR><LF>†
"ZM" (ASCII characters); "5678" represents fuel flow, right (tenths
gallons/hour)
ZN90123<CR><LF>†
"ZN" (ASCII characters); "90123" represents fuel used, right (tenths gallons)
ZO4567<CR><LF>†
"ZO" (ASCII characters); "4567" represents fuel flow, left (tenths gallons/hour)
ZP89012<CR><LF>†
"ZP" (ASCII characters); "89012" represents fuel used, left (tenths gallons)
ZQ345<CR><LF>
"ZQ" (ASCII characters); "345" represents error log/reason indicator
ZR678<CR><LF>
"ZR" (ASCII characters); "678" represents checksum
<ETX>
Where:
<STX>
start-transmit character (0x02)
<CR>
carriage-return character (0x0d)
<LF>
line-feed character (0x0a)
<+/->
sign indicator (0x2b["+"] or 0x2d["-"])
<ETX>
end-transmit character (0x03)
† Not available from Air Data Computer
Note
: Checksum is calculated by adding each byte in the message (including all characters from <STX>
up to and including the error log/reason indicator), such that carries are discarded to give a one byte
result. The ASCII-coded decimal representation of that byte is given, ranging from 0 (0x30, 0x30, 0x30)
to 255 (0x32, 0x35, 0x35).
Содержание GDL 88
Страница 1: ...190 01122 00 TBD 2011 Rev A...
Страница 2: ......
Страница 22: ...Page 3 4 GDL 88 TSO Installation Manual Rev A 190 01122 00 Figure 3 1 GPS Antenna Installation Considerations...
Страница 33: ...GDL 88 TSO Installation Manual Page 6 5 190 01122 00 Rev A...
Страница 34: ......
Страница 36: ...Page 7 2 GDL 88 TSO Installation Manual Rev A 190 01122 00...
Страница 41: ...GDL 88 TSO Installation Manual Page C 5 190 01122 00 Rev A Appendix C MECHANICAL DRAWINGS...
Страница 42: ...Page D 6 GDL 88 TSO Installation Manual Rev A 190 01122 00 Appendix D INTERCONNECT DIAGRAMS...
Страница 43: ...GDL 88 TSO Installation Manual Page D 7 190 01122 00 Rev A...
Страница 44: ......