G1000 Supplemental Maintenance Manual
Page 5-26
Textron Nav III Series
Revision 3
190-02128-04
NOTE
The 3
rd
item on the checklist instructs the operator to “prepare a detailed test
sequence with precise start and stop times for exercising all electronic devices”.
The list of relevant electronic devices is given in Table 5-3. Begin test with flaps
retracted, flight controls in a neutral position, all lights selected OFF.
Elapsed Time since Start of Test
(min:secs)
Action
0:00
Test begins
0:10
Navigation lights on
0:20
Navigation lights off
0:30
Landing lights on
0:40
Landing lights off
0:50
Recog/Taxi lights on
1:00
Recog/Taxi lights off
1:10
Strobes on
1:20
Strobes off
1:30
Beacon on
1:40
Beacon off
1:50
Pitot Heat on
2:00
Pitot Heat off
2:10
Aileron full right
2:20
Aileron full left
2:30
Flaps full down
3:00
Flaps full up
3:30
Rudder full left
3:40
Rudder full right
3:50
Elevator full nose UP
4:00
Elevator full nose DN
4:10
Elevator trim full nose UP
(manual)
4:40
Elevator trim full nose DN
(manual)
5:10
End of test
Table 5-3, Magnetometer Interference Test Sequence
6. When the CALIBRATE field is blinking, press the ENT key to begin the procedure, and
have a stopwatch ready to begin recording the elapsed time.
NOTE
It is important that the “time equals zero” moment corresponds with the
moment the PFD first displays the blinking TEST COMPLETE? Message.