12
If you will not have access to the back of the device after you
mount it, connect all necessary cables to the device before
placing it into the cutout.
NOTE:
To prevent corrosion of the metal contacts, cover
unused connectors with weather caps.
13
Install the rubber gasket pieces on the back of the device.
The pieces of the rubber gasket have adhesive on the back.
Make sure you remove the protective liner before installing
them on the device.
14
Place the device into the cradle.
15
Securely connect each cable to a port on the cradle.
16
Place the locking bracket over the cables.
17
Place the device into the cutout.
18
Secure the device to the mounting surface using the included
screws.
19
Install the trim caps by snapping them in place around the
edges of the device.
Installing the Swivel Base
Preparing to Run Cables under the Mounting Surface
NOTICE
Use pan-head screws or bolts when securing the swivel-mount
base. Screws or bolts with countersunk heads damage the
base.
Before you can prepare the swivel-mount base, you must
choose the location to install the mount and decide whether to
attach the mount using screws or bolts.
1
Remove the 10 mm M6x1 Phillips screw
À
and separate the
swivel mount
Á
from the base
Â
.
2
Orient the swivel base so the pass-through holes
Ã
face the
desired direction.
3
Using the swivel base as a template, mark the pilot hole
locations
Ä
.
4
Mark the cable routing hole
Å
.
5
Using the appropriate drill bit for the hardware, drill the three
pilot holes.
6
Using a
5
/
8
in. (16 mm) drill, drill a hole through the mounting
surface at the location you marked in step 4.
Fastening the Swivel Mount without the Cables
Running through the Mount
You should complete this procedure only if you are not running
the power and transducer cables under the mounting surface
and through the swivel-mount base.
1
Place the base
À
on the mounting surface, and fasten it
using the appropriate screws or bolts
Á
.
2
Place the swivel mount on the base, and replace the 10 mm
M6×1 Phillips screw.
3
Seal the cable pass-through holes with marine sealant.
Fastening the Swivel Mount with the Cables Running
through the Mount
You should complete this procedure only when running the
power and transducer cables under the mounting surface and
through the swivel-mount base.
1
Feed the cables through the 16 mm (
5
/
8
in.) center hole you
drilled when preparing to run cables beneath the mounting
surface.
2
Place the base on the mounting surface.
3
Route the cables through the cable pass-through holes.
4
Loosely fasten the base using the appropriate screws or
bolts.
5
Place the swivel mount on the base, but do not fasten it.
6
Place the cradle or device into the swivel mount (
).
7
Pull out enough slack from the power and transducer cables
so the mount can fully swivel to the desired positions when
the cables are connected.
8
Remove the cradle and the swivel mount from the base.
9
Apply marine sealant to the 16 mm (
5
/
8
in.) center hole and to
the cable pass-through holes.
10
Securely fasten the base with the appropriate screws or
bolts.
11
Place the swivel mount on the base, and fasten it using the
included 10 mm M6×1 Phillips screw.
2
echoMAP 40/50 Series Installation Instructions