Garland P10GXXA-X Скачать руководство пользователя страница 3

User Guide

UniversalTAP: Fiber Aggregator | P10GXXA-X | 4.22.1

Installation Procedure

1. The P10GXXA-X may be installed in any available 1U slot of a network rack and secured with rack

mount screws or in the optional rack mount bracket, sold separately. The optional rack mount bracket
is shown below.

2. Set the switches on the rear of the unit for the desired speed, LFP option and application.

3. Connect power cables to PS1 and PS2 on the rear panel and plug into available power sources.

4. Verify that the PS1 LED and PS2 LED on the rear panel are illuminated.

5. Insert the correct SFPs for the desired speed and application. This step can be done prior to power on

if desired.

6. Connect the fibers to the desired ports per the application.

7. Verify the L/A LEDs are illuminated green indicating link.

8. Verify the L/A LEDs are flashing green indicating link and traffic.

Optional Rack Mount Bracket

Garland Technology  |  716.242.8500  | garlandtechnology.com/support
Copyright © 2022 Garland Technology, LLC. All rights reserved.

3