Garland Ongard OG30 Скачать руководство пользователя страница 10

10

5. Wiring Instructions

FIGURE 3

OG20 / OG20LL

Interconnect

Smoke Alarm

OG30

Interconnect

Heat Alarm

OG10

Interconnect

Smoke Alarm

A

N

FUSE OR CIRCUIT BREAKER

Red

A

SW

N

Brown

Brown

Brown

Brown

Red

Red

Blue

Blue

Blue

Red

Blue

A

SW

N

A

SW

N

•  The maximum wire run distance between the first and last unit 

in an interconnected system is 307 meters. 

Figure 3

 illustrates 

interconnection wiring. Improper connection will result in damage 

to the alarm, failure to operate, or electrical shock hazard. 

•  Make certain alarms are wired to a continuous (non-switched) final  

sub-circuit.

Note: Use approved listed Australian Standards cable 1.0mm² 

TPS or larger as required by local codes.
FIGURE 3 “INTERCONNECT WIRING DIAGRAM”

ALARM HARNESS ------------------------  CONNECTED TO:
             Brown  -------------------------- A    (Hot Side of AC Line)
                 Blue -------------------------  N    (Neutral Side of AC Line)
                  Red ------------------------- SW  (Interconnect Lines (Red  

                                                             Wires) of Other Units in the  

                                                             Multiple Station Set up)

BATTERY INSTALLATION

See Battery replacement (section 10) for battery installation.

Содержание Ongard OG30

Страница 1: ...read this user guide which should be saved for future reference and passed on to any subsequent owner Heat Alarm with Hush User Guide 240V AC 50Hz 10mA 9V battery back up single and or multiple stati...

Страница 2: ...Safety Habits 18 14 What To Do When the Alarm Sounds 19 15 Warranty Contact Details 20 Thank you for purchasing this heat alarm It is an important part of your family s home safety plan You can trust...

Страница 3: ...10 minutes Alarm memory identifies which alarm has activated Optional use tamper resistant feature serves as a safeguard against tampering The heat alarm will sound a short beep about once every 40 se...

Страница 4: ...combination of 17 other alarm models Compatible Models include OG10 OG20 OG20LL OG30 Temperature Rating 57 C Maximum Ambient Temperature Rating 37 8 C Operating Temperature 0 C TO 40 C Operating Humi...

Страница 5: ...ern fire safety standards or if factors such as the presence of several young children elderly occupants or disabled people or smokers the use of portable heaters or solid fuel fires during the night...

Страница 6: ...N THIS AREA ANYWHERE IN THIS AREA 500mm 1000mm DEAD AIR ACCEPTABLE PLACEMENT 100mm If a ceiling mounting location is not possible the next logical location for mounting heat alarm is on the side wall...

Страница 7: ...ing see FIGURE 2B PEAK CEILING FIGURE 2B DEAD AIR DO NOT INSTALL SLOPED CEILING NOT IN THIS AREA 500mm ANYWHERE IN THIS AREA 1000mm In rooms with open joists or beams all ceiling mounted alarms shall...

Страница 8: ...t least one alarm close to the bedrooms For additional protection see Figure 1 Warning test your heat alarm operation after caravan or mobile home vehicle has been in storage before each trip and at l...

Страница 9: ...quare wave or modified square wave inverter These type of inverters are sometimes used to supply power to the structure in off grid installations such as solar or wind derived power sources These powe...

Страница 10: ...tion wiring Improper connection will result in damage to the alarm failure to operate or electrical shock hazard Make certain alarms are wired to a continuous non switched final sub circuit Note Use a...

Страница 11: ...RTS DO NOT TAMPER 1 Secure a suitable junction box near the position of the heat alarm ensure the quick connect cable length is long enough to reach the junction box for termination to be made 2 Conne...

Страница 12: ...ins power is present indicating normal operation Red LED blinks once every 10 seconds False Alarm Control activated Red LED OFF DC power is not present Red LED blinks once a second and unit is soundin...

Страница 13: ...is receiving AC power 2 Firmly depress and hold the Hush Test button for at least five 5 seconds The heat alarm will sound 3 long beeps pause 3 longs beeps repeating for up to 10 seconds after the Hu...

Страница 14: ...s the high temperature and sounds the alarm cannot be inadvertently silenced by the Hush Test button of other units In this case all of the alarms will continue to sound for as long as a dangerous sit...

Страница 15: ...Your Alarm Heat alarm sounds unwanted alarms 1 Hire an electrician to move heat alarm to a new location See Section 3 Installation Instructions and Section 4 Locations to Avoid Interconnected heat ala...

Страница 16: ...n open the battery door and install or replace the battery Install the battery to the battery terminal clip of the heat alarm When installing the battery press the battery lever down into the battery...

Страница 17: ...alarms should only be used to provide an added source of information and as a supplement to the smoke alarm installation Heat alarms do not always detect fires the fire may be a slow smoldering smoke...

Страница 18: ...windows and at least two 2 escape routes from each room Second story windows may need a rope or chain ladder Have a family meeting and discuss your escape plan showing everyone what to do in case of...

Страница 19: ...or Instead use your alternate exit If the inside of the door is cool place your shoulder against it open it slightly and be ready to slam it shut if heat and smoke rush in Stay close to the floor if t...

Страница 20: ...ACL 5 1 Garland s Products come within guarantees that cannot be excluded under the ACL 5 2 The Customer is entitled to a replacement or refund for major failure and for compensation for other reason...

Страница 21: ...make a claim If a defect in the product appears within the Warranty Period you are entitled to submit a warranty claim by first visiting the Garland website address below and filling out the Return F...

Страница 22: ...This warranty is provided by Madison Technologies 149 Beaconsfield St Silverwater NSW 2128 1800 66 99 99 www garlandcables com au ABN 56 010 669 379...

Отзывы: