![Garland Mealstream Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/garland/mealstream/mealstream_service-manual_3728510028.webp)
Mealstream Ovens Pt. No. 32Z3403 Issue 15
Page 28
WARNING
Before starting this test procedure please make sure that the oven is disconnected
from the electrical supply and that the oven power switch (ON/OFF) is in the OFF
position.
After each step check that the interlocks are operating in the correct order using a
continuity meter.
See Safety Code ( Page 4 )
Interlock
Order
SW1 (Monitor)
1
st
SW2 (Primary)
2
nd
Note both SW2 and SW3 activate together
SW3 (Secondary)
2
nd
Note both SW2 and SW3 activate together
Interlock
Order
SW1 (Monitor)
3
rd
SW2 (Primary)
1
st
Note both SW2 and SW3 activate together
SW3 (Secondary)
1
st
Note both SW2 and SW3 activate together
Step 1: Set the interlock so that they activate in the following order.
When closing the door.
When opening the door.
Continuity Meter
Spacer
No. required
Part No.
S5
Door Spacer 5mm
2
40C1118
S1
Door Spacer 1mm
2
40C1114
Door Spacer Kit
Part No. 10C0171
S10
Door Spacer 10mm
2
40C1119
Please Note
DO NOT attempt to carry out the following procedure
unless you have the following tools and parts.
PROCEDURE
FOR
DOOR INTERLOCK ADJUSTMENT
AND
TEST (2)
Disconnect the microswitches and check for the continuity of the switches with a continuity meter