background image

Part # 4521353 (06/17/09)

Page 19

FAULT FINDING

If servicing is required, we suggest that servicing be performed by your local authorized service agency or other competent 

persons, according to the law. 

Sealed Hotplates Diagnostics

PROBLEM

POSSIBLE CAUSE

SOLUTION

Water in pot does not boil 

or water takes too long 

to boil; with switch set to 

position “6”.

Pot has irregular bottom.

Use a flat bottom pot.

Pot too large for element size.

Use a smaller diameter pot

Pot too small for element size.

Use a larger diameter pot.

Element was preheated before  pot was 

placed on elements.

Allow element to cool protector. Protector 

will reset.

One element circuit may be defective.

Replace heating element.

Six heat switch my be defective.

Replace six heat switch.

Tubular Hotplates Diagnostics

PROBLEM

POSSIBLE CAUSE

SOLUTION

Hotplate too hot or cold.

Defective infinite switch.

Replace indefinite switch.

Hotplate not heating at all

Defective heating element.

Replace element.

Defective infinite switch.

Replace indefinite switch.

Fryer Diagnostics

PROBLEM

POSSIBLE CAUSE

SOLUTION

Power indicator is on. 

Heating indicator comes 

on. Fryer is not recovering 

or heating evenly.

One or more elements are defective.

Replace element.

Sensor is defective.

Replace sensor.

Thermostat is defective. 

Replace thermostat.

A contactor is defective. 

Replace contactor. 

Red indicator light is on. 

Fryer is not heating.

High temperature limit has been tripped. 

Lift the elements and reset the limit red 

button, the lower elements into fry tank. 

Thermostat may be defective.

Replace thermostat.

Contactor my be defective. 

Replace contactor. 

HI Limit may be defective.

Replace hi limit.

Power indicator is on. 

Heating indicator is off. 

Fryer is not heating. Red 

indicator is off. 

Sensor circuit open.

Check sensor connection/replace sensor.

Thermostat may be defective.

Replace thermostat.

Sensor my be defective.

Replace sensor.

Short circuit in sensor connection.

Check sensor connection/replace sensor.

Содержание EDU-15B

Страница 1: ...3903 GARLAND COMMERCIAL RANGES LTD 1177 Kamato Road Mississauga Ontario L4W 1X4 CANADA Phone 905 624 0260 Fax 905 624 5669 Part 4521353 06 17 09 2005 Garland Commercial Industries LLC FOR YOUR SAFETY...

Страница 2: ...Part 4521353 06 17 09 Page 2...

Страница 3: ...2 10 Wall Clearances 10 Electrical Supply 10 Controls 11 Before Operating the Griddle 11 Calibration Instructions 11 Broilers ModelsEDU 15B EDU 30B And EDU 42B 11 Wall Clearances 11 Electrical Supply...

Страница 4: ...5B 15 381 24 610 13 75 349 EDU 30B 30 762 24 610 13 75 349 EDU 42B 42 1067 24 610 13 75 349 EDU 15W 15 381 24 610 11 50 292 MODEL PRODUCT DESCRIPTION EDU 15HSE 15 381mm Wide Hot Plate With 8 203mm Sol...

Страница 5: ...22 2 22 2 22 2 66 6 EDU 15G 220V 2 8 2 8 0 0 0 0 12 8 0 0 0 0 12 8 230V 3 4 3 35 0 0 0 0 14 6 0 0 0 0 14 6 240V 3 4 3 35 0 0 0 0 14 0 0 0 0 0 14 0 EDU 24G 220V 380V 2N 5 6 2 8 2 8 0 0 12 8 12 8 0 0 25...

Страница 6: ...te and the packaging This type of supply must be used 4 Do not remove permanently fixed labels warnings or serial plates from the appliance for this many void approvals and create a safety hazard Prod...

Страница 7: ...r dangers and necessary precautions THESE APPLIANCES SHOULD NOT BE CLEANED WITH A WATER JET Ventilation The area in which the appliance is installed must be adequately ventilated to provide air for re...

Страница 8: ...sheet metal screws supplied Sanitary CounterTop Seal When appliance is installed without legs on a counter top it must be sealed in accordance with N S F standards as per the following instructions 1...

Страница 9: ...should be checked to ensure that the appliance electrical characteristics and the supply electrical characteristics agree The electrical supply must be adequate for the voltage phase and current mark...

Страница 10: ...hould there ever be an abnormal discrepancy in the set point and actual temperatures or repeated tripping of the new high limit occurs this fryer should be serviced by an authorized Garland service ag...

Страница 11: ...located in the dial shaft clockwise to decrease and counter clockwise to increase the temperature Example 1 4 Turn 18 C 35 F 7 Replace the thermostat dial and repeat steps 2 though 4 to verify that th...

Страница 12: ...loosen the two acorn nuts and hinge the control panel downward the thermal block is located on this area Controls Infinite switches energy regulators are used to control the elements High to 5 High h...

Страница 13: ...tank to bottom oil line stamped at the rear of the tank 9 liters 8 quarts This allows for oil expansion as heat is applied Do not fill with cold oil any higher than the bottom line overflow may occur...

Страница 14: ...heat 3 to Lo for low heat Setting the switches between any of the above numbers will give intermediate heat Switches are reversible and may be turned right or left Note Periodic checks should be made...

Страница 15: ...be an unsalted shorting or high temperature cooking oil 2 Set the griddle thermostat dial s to 55 C 130 F and heat the griddle surface until the oil begins to caramelize turning a golden brown Once th...

Страница 16: ...d spill build up a non metallic scouring pad can be used always rub in the direction of the grain of the metal to prevent scratching Rinse with a sponge dipped in clean hot water and dry thoroughly Re...

Страница 17: ...e faulty lamp 3 Install the replacement lamp in the control panel 4 Reassemble in reverse order Griddles Follow the instructions in Griddle installation calibration to check thermostat calibration SER...

Страница 18: ...he indicator lamp first turn off the electrical mains 1 Loosen the two acorn nuts securing the control panel and hinge the panel downwards SERVICING continued 2 Disconnect the supply wires to the lamp...

Страница 19: ...finite switch Hotplate not heating at all Defective heating element Replace element Defective infinite switch Replace indefinite switch Fryer Diagnostics PROBLEM POSSIBLE CAUSE SOLUTION Power indicato...

Страница 20: ...fore use Allow more time for griddle to saturate increase warm up time Broiler Diagnostics PROBLEM POSSIBLE CAUSE SOLUTION Casting too hot or not hot enough Defective infinite switch Replace infinite...

Страница 21: ...Part 4521353 06 17 09 Page 21...

Страница 22: ...Part 4521353 06 17 09 Page 22...

Страница 23: ...Part 4521353 06 17 09 Page 23...

Страница 24: ......

Отзывы: