![Garland CG-48F Скачать руководство пользователя страница 4](http://html.mh-extra.com/html/garland/cg-48f/cg-48f_installation-and-operation-manual_564333004.webp)
Part # 4520498 (01/08)
Page 4
DIMENSIONS AND SPECIFICATIONS
INSTALLATION
IMPORTANT:
The installation must comply with local codes,
or in the absence of local codes, with
CAN/CSA - B149 Installation Code – latest edition or with the
National Fuel Gas Code NFPA 54 ANSI Z22 .1 – latest edition .
All burner adjustments and settings shall be made by a
qualified gas technician .
Serial Plate Location
All burner inputs are shown on the Serial/Rating Plate of
each unit, located on the bottom of the control section near
the front .
When corresponding with the factory or your local
authorized factory service center regarding service problems
or replacement parts, be sure to refer to the particular unit
by the correct model number (including the prefix and suffix
letters and numbers) and the warranty serial number . The
rating plate contains this information .
INSTALLATION NOTES
MINIMUM SUPPLY PRESSURE REQUIRED
ELECTRICAL CHARACTERISTICS
Combustible Wall Clearances
Natural
Propane
Specifications
Sides
Back
7" W .C . (17 .4mbar)
11" W .C . (27 .4mbar)
120 V, Single Phase, 60Hz, 1 amp
6' (1829mm)
power supply cord provided
MANIFOLD PRESSURE REQUIRED,
AFTER BUILT-IN REGULATOR
6" (152mm)
6" (152mm)
.5” W .C . (8 .75 mbar)
10” W .C . (25mbar)
• IMPORTANT: Unit must be
installed on legs for proper
air circulation . A minimum 4”
(101mm) air space must be
maintained below unit for
required air flow to burners .
• Gas Input Ratings shown are for
installations up to 2,000 feet (610mm)
above sea level . BTU input ratings must
be derated for high altitude installations
• NOTE: No cord and plug on export
units . Direct connection to junction
box .
VENTILATION
EXPORT VOLTAGES
• Commercial cooking equipment
requires an adequate ventilation system .
Foradditional information, refer to the
National Fire Protection Association’s
Standard NFPA 96 .
• NOTE: Export voltages are available
on request .
ENTRY CLEARANCE
Crated
Uncrated
• 220-240 volt, 50 Hz, 0 .4 amps, single
phase .
40" (1016mm)
8" (965mm)
INPUT CHART - Natural Or Propane Gas
Model
Number
BTU/
HOUR
Kw
Gas
Inlet
Shipping Weight
LBS .
KGS .
CG-48F
120,000
5 .00
/4"
625
284
CG-60F
150,000
44 .00
/4"
765
48
CG-72F
180,000
52 .70
1"
905
411
Содержание CG-48F