background image

Part #GCGTRAINING06 (03/03/08)

Page 7

•  Each thermostat controls one zone burner though a 

dual solenoid-pressure regulator valve complete with a 

pressure test spigot . Check the manifold gas pressure on 

each combination valve to make sure it is the same as 

that shown on the serial plate . The gas pressure should be 

3 .5” WC for natural gas and 10 .0” for propane gas . 

•  For access to the pressure test spigots, turn the main 

power switch and all zone power switches to the OFF 

position and lower the front panel on its hinge . This is a 

safety precaution . The test spigots are at the rear of the rear 

of the combination regulator valves . 

•  Connect your manometer to the first valve for test and 

turn the manual shut-off valve to the ON position . 

NOTE

 : The shut off valve is under the unit . When it is ON and 

in the open position, the valve position is in line with the 

piping . Also, see the electrical procedure below for notes on 

the status indictor lights and setting the thermostats .

•  Turn the main power switch and the zone power switches 

to the ON position .

•  Set all the thermostat dials to 350˚F . When all the burners 

are operating, check and record the manometer reading, 

which should be the same manifold pressure as that 

specified on the serial plate (3 .5” WC for natural gas and 

10 .0” for propane gas) . Adjust the regulator to obtain the 

pressure rate specified . 

•  When satisfied with the reading obtained, turn the main 

power switch OFF . Remove the manometer test tube and 

re-cap the test spigot . 

•  Repeat this operation on each combination regulator 

valve to correctly set it . Then turn each thermostat, zone 

and main power switch OFF .

Electrical Power, Lighting & Control

WARNING

 : Do not work on ungrounded equipment . It is 

dangerous .

•  National and local electrical codes require that all devices 

of this type be electrically grounded . Check to make sure 

the unit is grounded .

CAUTION

 : Make sure the electrical connections enclosed by 

the panels are in good order and undamaged before closing 

and securing the front panels . 

NOTE 

: This griddle is equipped with a 3-pronged plug cord 

set to fit any 10V AC3-prong, 15 amp-rated, grounded 

receptacle . 

•  To check the unit lighting, turn the main power switch of 

the unit to the ON position . The green light of the power 

switch and the green indictor of the gas pilot of each 

section of the griddle should illuminate .

CAUTION

 : If after two minutes the pilot ignition fails, turn 

the main power switch OFF . Wait five minutes and switch the 

main power ON again .

•  When the green indicator for each zone is illuminated, 

turn the zone power switch for each zone ON . The 

thermostats can now be set to the desired temperature . 

•  The amber light burner indicator cycles with the 

operation of the thermostat . 

Ventilation

For efficient operation this unit requires a minimum 

ventilation air supply of 50frm . The ideal method of 

ventilation is a well-designed canopy of hood that exceeds 6” 

(15mm) beyond all sides of the unit . Ideally, the bottom of 

the hood should be set 6’6” (1981mm) from the floor .

Gas burners and pilot devices need a sufficient air supply to 

operate efficiently, so do not place large objects anywhere 

near them to restrict or in any way limit the air flow .

In most operations, the chain griddle will be used in 

conjunction with other kitchen equipment . The need for 

the ingress of air to the kitchen area must be sufficient to 

compensate for the air the ventilation system abstracts . 

Unless the air flow is sufficient a subnormal, and probable 

negative, atmospheric pressure will result, which will 

adversely affect the operation of the equipment and make 

work in the kitchen area unpleasant .

Start-Up

When the chain griddle is used for the first time, the griddle 

top requires seasoning . To season a griddle surface, follow 

this procedure .

1 .  Wash the griddle surface with a hot, mild detergent or 

soap solution, then rinse and dry thoroughly . 

 .  Set the thermostat to 175˚F for 30 minutes, then apply a 

film of cooking oil to the cooking surface and wipe away 

the excess .

3 .  After (5) five minutes, wipe the griddle plate clean .

INSTALLATION continued

Содержание CG-24

Страница 1: ...ssauga Ontario L W 1X CANADA Phone 905 6 0 60 Fax 905 6 5669 Enodis UK LTD Swallowfield Way Hayes Middlesex UB3 1DQ ENGLAND Telephone 081 561 0 33 Fax 081 8 8 00 1 Part GCGTRAINING06 03 03 08 006 Garl...

Страница 2: ...could expose you to airborne particles of glass wool ceramic fibers Inhalation of airborne particles of glass wool ceramic fibers is known to the state of California to cause cancer Operation of this...

Страница 3: ...ilation 7 Start Up 7 OPERATION MAINTENANCE 8 Cleaning 8 SERVICING 9 Have The Right Tools And Instruments 9 Adjustments 9 Pilot Flame Adjustment 9 Burner Air 9 Removing the Griddle Plate 9 Thermostat 1...

Страница 4: ...re available on request 40 1016mm 38 965mm 220 240 volt 50 Hz 0 4 amps single phase See illustration for further specifications size statistics FRONT VIEW Model CG 48R Optional Stand Finished Floor Gr...

Страница 5: ...es of the unit is what makes it so special Without fast response and a smooth gradient the chain griddle would be just another design among many Explaining why the unit is special is one thing and und...

Страница 6: ...late also specifies the type of gas required for the unit Also check that the electrical connections are in good order NOTE The chain griddle is certified for installation on a combustible base with m...

Страница 7: ...good order and undamaged before closing and securing the front panels NOTE This griddle is equipped with a 3 pronged plug cord set to fit any 120V AC3 prong 15 amp rated grounded receptacle To check t...

Страница 8: ...anual shut off gas valve and unplug the electrical power cord Cleaning 1 At the end of the cooking operations wipe and clean the unit while it is still warm Use a spatula to remove food residue and bu...

Страница 9: ...eld operator and are not considered to be defects in material or workmanship For this reason adjustments are not covered under the equipment warranty Pilot Flame Adjustment A pilot adjustment valve is...

Страница 10: ...ion from aging it can fail in two ways one from an open circuit that is a break in one of its wired the other when it short circuits If a thermocouple open circuits the thermostat will shut off and pr...

Страница 11: ...erial The green status light PL1 should illuminate when the main switch SW1 is closed If PL1 doesn t illuminate when SW1 is closed replace it Failure of the amber lights PL3 PL4 etc monitoring the zon...

Страница 12: ...Gas Valve Regulator Flow Flow Pressure setting screw Turn counter clockwise to increas the pressure setting Turn clockwise to decrease the pressure Inlet Power Switches Dust caps fitted on the main po...

Страница 13: ...Part GCGTRAINING06 03 03 08 Page 13 CONTROL PANEL SCHEMATIC DIAGRAM Figure 4 Control schematic for a Model CG 48 Chain Griddle...

Страница 14: ...he junctions are at different temperatures The current will continue to flow as along as the junctions T1 and T2 remain at different temperatures Thermoelectricity is the direct conversion of heat int...

Страница 15: ...the same temperature 350 F Allow the griddle plate to saturate and achieve a steady temperature Place a surface temperature probe on the griddle surface about the thermocouple you want to check The s...

Страница 16: ...5 419 5 449 5 479 5 509 220 5 509 5 540 5 570 5 600 5 630 5 661 5 691 5 721 5 752 5 782 5 812 230 5 812 5 843 5 873 5 903 5 934 5 964 5 994 6 025 6 055 6 085 6 116 240 6 116 6 146 6 176 6 207 6 237 6...

Страница 17: ...813 110 5 812 5 867 5 921 5 976 6 031 6 085 6 140 6 195 6 249 6 304 6 359 120 6 359 6 414 6 468 6 523 6 578 6 633 6 688 6 742 6 797 6 852 6 907 130 6 907 6 962 7 017 7 072 7 127 7 182 7 237 7 292 7 2...

Страница 18: ...Part GCGTRAINING06 03 03 08 Page 18...

Страница 19: ...Part GCGTRAINING06 03 03 08 Page 19...

Страница 20: ......

Отзывы: