![GAREN C01450 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/garen/c01450/c01450_manual_3569283004.webp)
MAIN MENU
To navigate through the options you must enter the main menu. When the display is in standby
press the
"ENTER"
button once to enter the menu. Use the
"UP"
and
"DOWN"
buttons to
choose functions from 0 to 9.
The led (LD_2) will light up symbolizing that it is inside the menu.
( 1 ) (TX)
Press the
"ENTER"
button to access the
"TX"
function.
Within the
"TX"
option you have two more options : Register and Delete
Using the
"UP"
or
"DOWN"
buttons, choose
“C”
to register or
"A"
to delete.
1.1
(C) REGISTER:
After choosing the letter
"C"
, click on the
"ENTER"
button to enter
the function "
REGISTER
".
1.1.1.
Already in the function, the display will clear. Press the button of the control you want to
register, the letter
"C"
will appear, signaling that you have identified a control, press and release
the "
ENTER
" button, then the letter
"P"
will appear confirming the recording. The electronic
central will wait for new buttons to be registered, or to exit, press
"ENTER"
once or wait 10 seconds
1.2 (A) DELETE:
After choosing the letter "
A
", click the "
ENTER
" button to enter the
function "
DELETE
".
1.2.1
Already in the function, press and release the "
UP
" button until the display shows the
letter "
A
". Press the button
“ENTER”
to confirm.
The led(LD_2) will flash until the electronic central has finished erasing the memory.
After finishing, the panel will return to the main menu.
(2) STROKE
= (First activation of the motor)
It’s necessary to program the stroke before any activation to avoid damage to the electronic
central and gate.
Press the "
ENTER
" button to access the "
STROKE
" function.
Within the
"STROKE"
you have two more options: Program Stroke and Adjust
Using the "
UP
" or "
DOWN
" buttons to navigate until the letters "
C
” for Program Stroke or "
A
” for
Adjustment appear on the display.
2.1 (C) PROGRAM STROKE:
After choosing the letter "
C
", click the "
ENTER
" button to
enter the function
“PROGRAM STROKE”
.
2.1.1.
Already in the function, press the
"UP"
or
"DOWN"
button until the letter
"C"
appears in
the display. Press the button
“ENTER”
for the engine to start moving and look for the limit switch.
NOTE:
First operation must be the closure, otherwise the wires must be reversed
of the
“U”
motor through
“W”
and also the limit switch. Then remove and replace the jumper of
the
"TAMPER".
When the limit switch is found, the letter
“c”
will appear on the display, which means to
continue, press and release the
“ENTER”
again for the engine to run to the other limit switch,
then the letter
“P”
will appear on the display meaning that the stroke has been programmed
correctly.
2.2 (A) ADJUST
: It serves to fix the ends of the opening and closing limit switches. After
choosing the letter
"a"
, click the
"ENTER"
button to enter the
"ADJUSTMENT"
function.
2.2.1.
Already in the function with the
"UP"
button pressed, the automator moves in the
opening direction, and the "
DOWN
" button in the closing direction.
(3) (SPEED)
Maximum speed achieved during opening or closing. Press the "
ENTER
" button to access the
"
SPEED
" function.
Using the "
UP
" or "
DOWN
" buttons, choose
" A "
for Opening or
" F "
for Closing.
3.1 (A) OPENING:
After choosing the letter "
A
", click the "
ENTER
" button to enter the
"OPEN"
function.
Already in the function, press the
"UP"
or "
DOWN
" button to increase or decrease the motor
speed from 45Hz to 180Hz, "0" = 45Hz, "9" = 180Hz (Increase and decrease of 15Hz).
3.2 (F) CLOSURE:
After choosing the letter
"F"
, click the
"ENTER"
button to enter the
"
CLOSE
" function.
Already in the function, press the "
UP
" or "
DOWN
" button to increase or decrease the motor
speed from 45Hz to 180Hz, "0" = 45Hz, "9" = 180Hz (Increase and decrease of 15Hz).
(4) (FINAL SPEED)
Motor speed in hertz (Hz) during the course learning and after the deceleration of the arrival
near the end of stroke.
Press the "
ENTER
" button to access the "
FINAL SPEED
" function.
Within the "
FINAL SPEED
" option you have 10 adjustment levels.
Press the “
UP
” or
“DOWN”
key to increase or decrease the final speed, which goes from 15Hz to 60Hz, "0" =
15Hz, "9"
= 60Hz (Increase and decrease of 5Hz).
(5) (RAMP)
Distance from the stop where the motor will slow down. The values refer to the percentage of
the course learned.
Press the "
ENTER
" button to access the "
RAMP
" function.
Using the "
UP
" or "
DOWN
" buttons, choose " A " for Opening or
" F "
for Closing.
5.1 (A) OPENING:
After choosing the letter "
A
", click the "
ENTER
" button to enter the function
“OPENING”
.
Already in function, press the "
UP
" or "
DOWN
" button to increase or decrease the size of the
ramp that the motor will run, from 15% to 60%, "0" = 15%, "9" = 60% (Increase and decrease
of 5Hz).
5.2 (F) CLOSURE:
After choosing the letter "
F
", click the "
ENTER
" button to enter the in the
"
CLOSURE
" function.
5
6
Содержание C01450
Страница 1: ...Manual C01450 CENTRAL TSiLight...