background image

4

Section 1: SAFETY INFORMATION

 
I.10   CAUTION: To prevent injury....
I.11

    Never operate this product if it has a damaged cord or plug.  If it is not working properly, has been

 

dropped, damaged or has fallen into water, please return the product to a Welch service center for 

 

examination and repair.

I.12

    Keep the cord away from the heated surfaces.

I.13

   Never block any air openings or place it on a soft surface where the openings may be blocked.  

 

The air openings are for ventilation of the motor inside the housing.  Keep all air openings free of lint, 

 

dirt and other foreign objects.

I.14

    The PTFE pump is thermally protected and can automatically restart when the protector resets.

 

Always disconnect power source before servicing.

I.15

    Wear safety glasses or goggles when operating this product.

I.16

   Use only in well ventilated areas.  The motor is fan cooled enclosed in a shell.  

 
 
 
 
 
 
 
 
 
 
 
 

I.17

    All electrical products generate heat.  To avoid serious burns never touch unit during or immediately 

 

after operation.

I.18

   Be sure to properly identify intake and discharge before using pump.  See Section II-5.

 

 

 

 

 

 

 

I.20   CAUTION: To reduce risk of electrical shock....
I.21

 

Do not disassemble.  Disassembly or attempted repairs if accomplished incorrectly can create 

 

electrical shock hazard.  Refer servicing to qualifi ed service agencies only:

 

Call (847) 676-8800 Ext. 1

I.22

 

Unit is supplied with a three  pronged plug.  Be sure to connect pump to a properly grounded 

 

outlet only.

I.23

     WARNING:  To reduce risk of electricution…

I.24

    Do not use this product in or near area where it can fall or be pulled into water or other liquids.

I.25

    Do not reach for this product if it has fallen into liquid.  Unplug immediately.

I.26

    Never operate this product outdoors in the rain or in a wet area.

I.27

    DANGER:  To reduce risk of  explosion or fi re…

I.28

    Do not use this pump near explosive atmospheres or where aerosol (spray) products are being used.

I.29

    Do not use this product near fl ames.

WARNING

Do not operate the pumps in an atmosphere containing 

flammable or explosive gases/vapors.

WARNING

Never block the exhaust port.  If the exhaust is blocked, pressure 

will build-up in the pump with the potential of the pump head 

bursting and causing possible injury to personnel in the area.

WARNING

Failure to observe the above safety precautions could result 

in severe bodily injury, including death in extreme cases.

Содержание Welch 2580B-01

Страница 1: ...0B 50 2580C 50 2585C 02 2585C 05 2585C 50 2585C 55 2585C 57 Warning Not recommended for pumping acid base or organic vapors or gases Warning Be sure to properly identify intake and discharge before us...

Страница 2: ...ons are found where failure to observe the instruction could result in damage to the equipment associated equipment and process These units con rm to the SI International system of units of measuremen...

Страница 3: ...ions 3 01 Speci cation Chart Section 04 Motor Power Speci cations Features 4 01 Motor Speci cation Chart 4 02 Changing the Voltage Settings for Global Motor Option on A Models 4 03 Changing the Voltag...

Страница 4: ...ion II 5 I 20 CAUTION To reduce risk of electrical shock I 21 Do not disassemble Disassembly or attempted repairs if accomplished incorrectly can create electrical shock hazard Refer servicing to qual...

Страница 5: ...or indirect moisture contact The pump should be located as closely to its system in order to utilize it most e ciently The pump is rated for indoor use only Maximum altitude 2000 meters Operating tem...

Страница 6: ...rrected 2 23 Identi cation Symbols 2 24 Grounding Instructions This product should be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providing an...

Страница 7: ...monly used to indicate vacuum level when operating in the rough vacuum range 0 to 29 9 Hg Dial vacuum gauges give negative pressure that is pressure below atmospheric The reference point for the gauge...

Страница 8: ...s if you have droplets coming out of the exhaust port If you see droplets of water Welch recommends you use a cold trap to capture the water before entering the pump or dilute the water vapor stream b...

Страница 9: ...suspected area with a thick soap solution Escaping air will produce soap bubbles 3 14 Operating Pressure Range Model 2581 Dry Vacuum Pumps are designed to be run from atmospheric to their maximum vacu...

Страница 10: ...n for the condition of the pump is the determination of its maximum vacuum capability This can be accomplished by blocking of the intake and reading the vacuum level on the gauge See Section 2 8 5 11...

Страница 11: ...30 5 12 0 30 5 Shipping Weight lbs 27 5 27 5 Kg 12 5 12 5 Shipping Dimensions L in Inches cm 19 5 49 5 19 5 49 5 W in Inches cm 20 5 52 0 20 5 52 0 H in Inches cm 16 0 40 6 16 0 40 6 Catalog Number C...

Страница 12: ...12 6 11 Pumping Speed Curves...

Страница 13: ...13 6 12 Dimensional Drawing Dimensions of Pump Model 2580 2585 inches A B C D E F G H I J K L M N 12 5 11 69 7 37 5 25 10 5 8 5 9 5 8 75 3 06 0 75 4 62 0 75 4 5 6...

Страница 14: ...0K 04 1 2 Note 1 Connecting Rod Assembly 2 2 2 Note 1 O Ring Valve Plate 2 2 3 2 Note 1 O Ring Connector Tube 4 4 4 1 Note 1 Head Screw 8 5 2 Note 1 Rubber Suction Feet 4 6 2 Note 1 Valve Plate Assemb...

Страница 15: ...maximum vacuum readings from day to day The preset vacuum level may be adjusted by opening or closing the ori ce A small leak through the ori ce is provided to allow easy restart of the pump if you a...

Страница 16: ...erative No other warranties are expressed or implied The method of executing this warranty servicing adjusting repairing or replacing shall be at the discretion of Gardner Denver Welch Vacuum Technolo...

Отзывы: