13-17-605 Page 80
SYMPTOM
POSSIBLE CAUSE
REMEDY
Oil carryover
1.
Overfilling oil separation vessel
1.
Drain excess oil from system.
2.
Clogged oil return line orifice
2.
Inspect and service.
3.
Clogged oil return line strainer
3.
Inspect and service.
4.
Clogged, broken, or loose oil
return line fittings
4.
Inspect and tighten or replace.
5.
Ruptured oil separator element.
5.
Replace element.
6.
Loose assembly
6.
Tighten all fittings and gaskets.
7.
Foam caused by use of
incorrect oil
7.
Use Gardner Denver AEON 9000TH
oil only.
8.
Minimum pressure valve
malfunction
– discharge
pressure below 80 psig
8.
Repair or replace.
Содержание VST110
Страница 34: ...13 17 605 Page 33 Figure 4 3 PIPING AND INSTRUMENTATION ILLUSTRATION 300VST797 B Ref Drawing...
Страница 35: ...13 17 605 Page 34 Figure 4 4 WIRING DIAGRAM AIR COOLED Two Stage VS Control 300VST546 C Ref Drawing Page 1 of 4...
Страница 36: ...13 17 605 Page 35 Figure 4 5 WIRING DIAGRAM AIR COOLED Two Stage VS Control 300VST546 C Ref Drawing Page 2 of 4...
Страница 37: ...13 17 605 Page 36 Figure 4 6 WIRING DIAGRAM AIR COOLED Two Stage VS Control 300VST546 C Ref Drawing Page 3 of 4...
Страница 38: ...13 17 605 Page 37 Figure 4 7 WIRING DIAGRAM AIR COOLED Two Stage VS Control 300VST546 C Ref Drawing Page 4 of 4...
Страница 65: ...13 17 605 Page 64 Figure 8 4 COUPLING INSTALLATION TOOL KIT Figure 8 5 COUPLING REMOVAL TOOL KIT...
Страница 67: ...13 17 605 Page 66 Figure 9 1 MINIMUM DISCHARGE PRESSURE CHECK VALVE...
Страница 70: ...13 17 605 Page 69 Figure 10 2 INLET CONTROL VALVE ACTUATOR...
Страница 82: ......
Страница 83: ......