background image

6

2.4 Timer Drain Programming Mode

1.   Press the “Drain Interval Program” button (the 

“Condensate Draining” LED will start to flash, and 

the illuminated LED on the “Dew Point Temperature 

Indicator” will identify the factory setting for “Minutes 

Between Drain Cycles.” (See Table 1)

2.   Press and release the “Drain Interval Selector” button to 

sequence the “Minutes Between Drain Cycle LED’s” from 

left to right until reaching your selection.  The “Red” LED 

is not used (Reference Table 2 for “Drain Cycle Intervals”)

3.   To initiate the new setting, press the “Drain Interval 

Program” button (this will store the new setting and exit 

the program).

4.   Exiting the Program will cause the Timer Drain to 

discharge and begin a new cycle.

NOTE:

  Failure to perform step 3 within 25 seconds of 

completing step 2 will cause the unit to revert back to the 

previous setting.

NOTE:

  In the event of a brief or extended period of power 

loss, the unit will retain the existing program setting and will 

begin a new cycle once power is reapplied. Had drain been 

ready to drain before the loss of power, the drain bowl’s 

capacity would prevent downstream flooding. Condensate 

will drain completely within a couple of cycles. (Manually 

pressing the “Push-to-Test” button would drain bowl 

immediately)

2.5  Operating check points 

Check the following on a periodic basis:

A.   Green power on light is illuminated.

B.   Dewpoint indicator is in green area.

C.   Condensate is discharging from drain.

2.6  I-Controller Level 4

 

(Optional on models RNC200-RNC750)

Energize dryer.  Green power on light will illuminate.

IMPORTANT:  Energize dryer disconnect switch (provided by 

others, see NEC) 24 hours before refrigeration compressor 

is started!  Never use the disconnect switch to shutdown the 

dryer for a extended period of time (except for repair).  Failure 

to follow these instructions may result in a non-warrantable 

compressor failure.

NOTE:  If there is no power to the control board for a period 

of two weeks or more, it may return to the default mode.

A. 

Program Monitor

Press and hold Program Mode button until Main Menu screen 

appears.  Use the Up and Down arrow buttons to scroll through 

the list of submenu choices.  Press Enter button to view the 

submenu that is displayed.  Press ESC to exit the Main Menu 

and return to Display mode.

Table 2  LED Legend  

LED

Illuminated

Minutes

between

Drain Cycles

1

st

1

2

nd

3

3

rd

5

4

th

10

5

th

20

6

th

30

7

th

40

8

th

50

9

th

60

Condensate Draining 

(Flashes in

programming mode)

Drain Interval

Program

Dew Point 

Temperature Indica-

tor

Drain Interval

Selector

(LED illuminated 

indicates drain cycle 

setting)

Table 1  Timed drain illuminated LED Settings

Inlet Pressure

75

100*

125

150

200

225

Dryer Model

RNC100

3

3

4

4

4

4

RNC125

3

3

3

3

4

4

RNC150

2

3

3

3

3

4

RNC200

2

3

3

3

3

3

RNC250

2

2

2

3

3

3

RNC300

1

2

2

2

3

3

RNC400

1

2

2

3

3

4

RNC500

1

1

2

2

3

3

RNC600

1

1

1

2

2

3

RNC750

1

1

1

1

2

2

*  Recommended and pre-programmed factory settings for each RNC 

Series model dryer. Assumes CAGI ADF100 inlet conditions with 100°F 
ambient and 10°F air-cooled aftercooler approach temperature.

2.3 Timer Drain

  

(Only Models with I-Controller Level 2)

NOTE:

  The Timer Drain LED level has been pre-programmed 

at the factory for your specific RNC Series dryer. 

Programming is based upon a minimum of 100 psi saturated 

inlet air pressure and maximum energy efficiency. The drain 

open time is fixed at one second and a small amount of air 

will be exhausted with each cycle. Generally, no adjustment to 

the timer is required.

 If water is present downstream of the dryer, 

always verify that any condensate drains installed upstream of 

the dryer are draining properly before attempting to readjust 

the LED setting.
1.  For minimum inlet air pressures that fall between 

column values, the setting for the lower pressure is 

recommended. (i.e. select the 100 psi column values for 

124 psi inlet pressure listed in Table 1.)

2.  Where the dryer is consistently operating at less than 

maximum capacity, it may be possible to increase the LED 

set point to minimize air loss. Discretionary adjustments 

to the dryer should only be made on a hot, humid day 

when the maximum expected air load is flowing through 

the dryer. Failure to do so may prevent the condensate 

from draining completely when operating under peak 

load conditions.

Содержание RNC100

Страница 1: ...NG DIAGRAM I Controller Level 2 Model 100 thru 150 115 or 208 230V 60 Hz 100 or 240V 50 Hz 17 Models 200 thru 600 230 400 460V 3 50 60 Hz 18 19 Model 750 230 400 460V 3 50 60 Hz 20 21 WIRING DIAGRAM I...

Страница 2: ...our plant It was received in good condition by the carrier and was so acknowledged Check for Visible Loss or Damage If this shipment shows evidence of loss or damage at time of delivery to you insist...

Страница 3: ...is and has not been preset at the factory for this altitude contact manufacturer s Service Department G The installation of a flexible connection prior to the dryer is recommended to prevent possible...

Страница 4: ...DELS 500 600 and 750 CHECK FOR CORRECT PHASING OF UNIT After starting the dryer if an unusual noise is heard or if the discharge line does not get hot the refrigeration compressor may be running in th...

Страница 5: ...F 49 C D Maximum ambient temperature Air cooled models 110 F 43 C Water cooled models 130 F 54 C E Minimum ambient temperature 40 F 4 C 2 2 Start up IMPORTANT Energize dryer disconnect switch provide...

Страница 6: ...tton until Main Menu screen appears Use the Up and Down arrow buttons to scroll through the list of submenu choices Press Enter button to view the submenu that is displayed Press ESC to exit the Main...

Страница 7: ...urs that refrigeration compressor is operating are counted b Press ESC at any time to return to the Main Menu NOTE On dryers with air cooled condensers regular condenser cleaning is recommended Dirtin...

Страница 8: ...compressor off when power is restored after power interruption 7 To reinstitute SCHEDULE RUNNING push Schedule On Off and Enter button IMPORTANT Dryer must be energized 24 hours before refrigeration...

Страница 9: ...he following for proper drain function Automatic Draining Valve handle should be positioned parallel to the valve body as shown with the arrow on the handle pointing toward the EDD In this position co...

Страница 10: ...EPRESSURIZE BEFORE SERVICING If filter has not been depressurized before disassembly an audible alarm will sound when the bowl begins to be removed from the head If this occurs stop disassembly isolat...

Страница 11: ...parator weekly by pushing test button on control panel 3 5 Rebuild drain mechanism annually To facilitate service maintenance kits are available See page 26 Models RNC200 thru RNC750 Separator Element...

Страница 12: ...led models scfm 60 Hz 50 Hz 100 84 125 105 150 125 200 170 250 210 RNC MODEL 300 400 500 600 750 Rated capacity of air cooled models scfm 60 Hz 50 Hz 300 250 400 340 500 420 600 540 750 630 TABLE 2 Ai...

Страница 13: ...60 Hz N A 1 1 2 0 50 Hz N A 0 9 1 7 Electrical Data Nominal Voltage 115 1 60 208 230 3 60 Min Max Voltage 104 127 187 253 Input Power Rated Flow watts 875 1070 1100 1255 1962 Rated Load Amps 9 5 13 0...

Страница 14: ...sig 2 8 barg minimum Flow Required with 85 F Cooling Water gallons per minute 60 Hz 2 0 2 1 4 9 6 8 50 Hz 1 7 1 8 4 1 5 6 Electrical Data Nominal Voltage 208 230 3 60 Min Max Voltage 187 253 Input Pow...

Страница 15: ...2 600 30 15 766 30 15 766 30 15 766 30 15 766 30 15 766 30 15 766 30 15 766 E 17 62 448 17 62 448 17 62 448 30 15 766 30 15 766 30 15 766 30 15 766 39 62 1006 39 62 1006 39 62 1006 F 19 62 498 19 62 4...

Страница 16: ...1 L2 230 VAC CUSTOMER SUPPLIED L1 PE POWER ON PILOT LIGHT T2 T2 T2 T1 T1 PE T2 T1 T1 FPS 1 FAN 1 MTR2 START RELAY SR SR L3 L3 M 6 5 S CAPACITOR 4 OVERLOAD 3 1 3 MTR1 COMPRESSOR R C S 120 VAC POWER COR...

Страница 17: ...GROUND STUD PE FAN 1 HARNESS C 1 FAN 1 MTR2 FPS 1 COMPRESSOR MTR1 DRAIN NEUTRAL COMPRESSOR ON L1 L1 N L1 1 1 N L1 1L1 N 1 N GROUND STUD 6 7 J5 3 5 4 1 2 N N COMPRESSOR CONTACTOR N TO GROUND STUD PE N...

Страница 18: ...HARNESS 1L2 L3 TB2 TB2 PE T3 T2 H1 HEATER 1 for 500 600 models only FAN 2 HARNESS FPS 2 FAN 2 REF SHEET 02 LINE 18 REF SHEET 01 LINE 19 03 10 11 12 09 08 07 06 05 04 L3 L3 L3 L2 L2 02 01 00 PE TB1 L1...

Страница 19: ...M SHEET 01 X X X X THERMISTER IC2 LEVEL BOARD DRAIN NEUTRAL DRAIN LINE THERMISTER NEUTRAL 3 N N HPS 1 LINE 1 1 1 TB2 DRAIN HARNESS GRN YELLOW GRN YELLOW DRAIN HARNESS DRAIN HARNESS PE PE TB2 X PE 3 BR...

Страница 20: ...ESS 1L2 L3 TB2 TB2 PE T3 T2 H1 HEATER 1 FAN 2 HARNESS FPS 2 FAN 2 REF SHEET 02 LINE 12 REF SHEET 01 LINE 20 03 10 11 12 09 08 07 06 05 04 L3 L3 L3 L2 L2 02 01 00 PE L1 L1 L1 L3 L2 TB1 L1 L3 L2 CONT 1...

Страница 21: ...EET 01 X X X X THERMISTER IC2 LEVEL BOARD DRAIN NEUTRAL DRAIN LINE THERMISTER NEUTRAL 3 N N HPS 1 LINE 1 TB2 DRAIN HARNESS GRN YELLOW GRN YELLOW DRAIN HARNESS DRAIN HARNESS PE PE TB2 X PE 3 BROWN BLUE...

Страница 22: ...RNESS 1L2 L3 TB2 TB2 PE T3 T2 H1 HEATER 1 for 500 600 models only FAN 2 HARNESS FPS 2 FAN 2 REF SHEET 02 LINE 11 REF SHEET 02 LINE 10 REF SHEET 01 LINE 20 03 10 11 12 09 08 07 06 05 04 L3 L3 L3 L2 L2...

Страница 23: ...larm A N O W15 W13 W14 W11 W10 W9 W8 W21 W19 Alarm B N C Alarm B Com Drain Test Output Alarm B N O Drain Test Output Compressor 1 Output Compressor 1 Output W27 W18 W17 W16 N A N A W25 W23 FROM SHEET...

Страница 24: ...T3 T2 H1 HEATER 1 FAN 2 HARNESS FPS 2 FAN 2 REF SHEET 02 LINE 11 REF SHEET 02 LINE 10 REF SHEET 01 LINE 20 03 10 11 12 09 08 07 06 05 04 L3 L3 L3 L2 L2 02 01 00 PE L1 L1 L1 L2 L3 TB1 L1 L3 L2 CONT 1 D...

Страница 25: ...rm A N O W15 W13 W14 W11 W10 W9 W8 W21 W19 Alarm B N C Alarm B Com Drain Test Output Alarm B N O Drain Test Output Compressor 1 Output Compressor 1 Output W27 W18 W17 W16 N A N A W25 W23 FROM SHEET 01...

Страница 26: ...X2 X3 X4 PE L3 L2 L1 TB2 FU1 M FU2 M FU3 M FU1 P FU2 P FU3 P 575V VOLTAGE OPTION 575V 460V TRANSFORMER BANK 460V CONNECTION 460 3 60 CUSTOMER CONNECTION PRIMARY FUSE ENCLOSURE 575 3 60 CONNECTION CUS...

Страница 27: ...ss dryer 1 Excessive air flow 2 Freezing of moisture in evaporator because of refrigeration system fault 3 Separator or optional Oil Removal filter element clogged Check flow rate See D below Replace...

Страница 28: ...ant a Lack of condenser cooling Air cooled Ambient temperature too high clogged condenser fins obstructed flow across condenser faulty fan motor or fan control switch Water cooled Cooling temperature...

Страница 29: ...l Right Lower G5002271 G5002271 G5002271 REPLACEMENT CABINET PARTS Models RNC200 through RNC750 2 5 3 6 1 4 ID PARTS DESCRIPTION 200 250 300 400 500 600 750 1 Cabinet Panel Top G5002276 G5002276 G5002...

Страница 30: ...ON REFERENCE RIGHT REAR VIEW A covers and center support shelf removed for clarity 2 9 12 7 8 10 11 15 18 16 17 1 3 4 RIGHT FRONT VIEW B covers and center support shelf removed for clarity 7 8 10 2 9...

Страница 31: ...ot Gas Bypass Valve G5002350 G5002350 G5002350 G5002350 G5002350 G5002350 G5002350 G5002350 G5002350 10 Condenser G5002249 G5002249 G5002249 G3232828 G3232828 G3232828 G3232828 G3232828 G3232828 11 Fi...

Страница 32: ...EFERENCE RIGHT REAR VIEW A covers and center support shelf removed for clarity 33F 39F 1C 4C 23 7 2 8 1 24 3 25 IC2 Control Panel RIGHT FRONT VIEW B covers and center support shelf removed for clarity...

Страница 33: ...G3227172 G3227172 G3227172 G3227172 G3227172 G3227172 G3227172 G3227172 19 Digital PC Board IC 4 G3227156 G3227156 G3227156 G3227156 G3227156 G3227156 G3227156 G3227156 G3227156 G3227145 20 Digital P...

Страница 34: ...ORIENTATION REFERENCE RIGHT REAR VIEW A covers and center support shelf removed for clarity 33F 39F 1C 4C 18 4 2 3 1 7 5 19 20 IC2 Control Panel RIGHT FRONT VIEW B covers and center support shelf rem...

Страница 35: ...erature Sensor IC 2 G3210926 G3210926 G3210926 G3210926 G3210926 G3210926 G3210926 G3210926 G3210926 G3210926 17 Temperature Sensor IC 4 G3210926 G3210926 G3210926 G3210926 G3210926 G3210926 G3210926...

Страница 36: ...ED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE THE MANUFACTURER SHALL NOT BE LIABLE FOR LOSS OR DAMAGE BY REASON OF STRICT LIABILITY IN TORT OR ITS NEGLIGENCE IN WHATEVER MANNER INCLUDING DESIGN MANU...

Отзывы: