2.3 INSTALLATION LAYOUT - CORRECTION FACTORS
Type A
installation is suggested when the compressor operates at reduced intermittence and the total consumption
equals the compressor flow rate.
Type B
installation is suggested when the air consumption can consistently change with peak values highly exceeding the
flow rate of the compressors. The capacity of the tank must be sized in order to compensate for more demanding
conditions (peak air consumption).
CORRECTION FACTOR FOR OPERATING PRESSURE CHANGES:
PSIG
80
100
150
200
230
FACTOR
1.25
1.00
.87
.83
.80
CORRECTION FACTOR FOR AMBIENT TEMPERATURE CHANGES:
ºF
85
100
105
110
FACTOR
.91
1.00
1.10
1.22
CORRECTION FACTOR FOR INLET AIR TEMPERATURE CHANGES:
ºF
125
150
180
200
FACTOR
.85
.91
1.00
1.11
1 AIR COMPRESSOR
5 DRYER
2 PRE-FILTER
6 BY-PASS
3 COMPRESSED AIR TANK
7 CONDENSATE DRAIN
4 AFTERFILTER
2
7
7
7
3
4
5
6
1
2
1
7
5
6
3
7
7
4