ELECTRICAL SCHEMATICS

Model RGD75A1

115V/1PH/60Hz (Standard)

N

L

E

Fan motor

LEGEND

CR : Running capacitor

M2 : Fan motor

S2 : Overload Protector

S3 : Fan pressure switch

S1 : Switch "on-off"

T1 : Electric drain timer

GL1 : Green Lamp 

S0 : Main switch(Customer's installation)

Drain valve & timer

Customer's installation

Ref. Compressor

M1

C

S

M

R

S2

CR

SOL1 : Electric drain
SK1 : Spark Killer

(Resistance: 120Ω + Capacitor: 0.1uF)

M1 : Ref. Compressor

GL1

S1

L

N

S0

S3

L1

N1

T1

SOL1

M2

SK1

2

3

LEGEND

 

CR:  Running Capacitor

 

M1:  Ref. Compressor

 

M2:  Fan Motor

 

S1:  Switch "on-off"

 

S2:  Overload Protector

 

S3:  Fan Pressure Switch

  GL1:  Green Lamp

 

S0:  Main Switch (Customer's installation)

 

T1:  Electric Drain Timer

  SOL1:  Electric Drain

  SK1:  Spark Killer (Resistance: 120Ω + Capacitor: 0.1uF)

Содержание RGD Series

Страница 1: ...r visit Sales and Service at www gardnerdenverproducts com 7442624 Rev C 08 20 INSTRUCTION MANUAL RGD Series Models RGD75A1 RGD100A1 RGD125A1 RGD150A1 RGD200A4 RGD250A4 RGD300A4 RGD400A4 RGD500A4 REFR...

Страница 2: ...ENERAL ARRANGEMENT DRAWINGS Models RGD75A1 through RGD150A1 9 Models RGD200A4 through RGD250A4 10 Models RGD300A4 through RGD500A4 11 ELECTRICAL SCHEMATICS Model RGD75A1 12 Models RGD100A1 through RGD...

Страница 3: ...ations for the requirements for breathing quality air RECEIVING MOVING AND UNPACKING A RECEIVING This shipment has been thoroughly checked packed and inspected before leaving our plant It was received...

Страница 4: ...the bypass line Compressed air systems commonly require filters to remove compressor oils particulates condensed liquids and other contaminants When an oil removal filter is used it should be install...

Страница 5: ...5A1 and RGD150A1 1 7 3 4 10 9 2 8 5 6 Dryer System Monitor Models RGD200A4 RGD250A4 RGD300A4 RGD400A4 and RGD500A4 1 On Off Switch Press the top of the switch I to turn the dryer on Press the bottom o...

Страница 6: ...dryer are draining properly before attempting to adjust the timer settings 1 For minimum inlet air pressures that fall between column values the setting for the lower pressure is recommended i e selec...

Страница 7: ...nical repairs are to be made or service is performed vent the internal pressure of the dryer to atmospheric pressure Restart the dryer according to the start up instructions Disconnect power supply an...

Страница 8: ...e performed 1 Inspect internal parts of valve body clean or replace as required NOTE Replace solenoid valve if component damage is observed 2 Remove debris from valve body 3 Wipe solenoid core compone...

Страница 9: ...e if necessary Ambient temperature too high Verify ambient temperature throughout day High pressure switch activated models 200 to 500 only Press manual reset button to switch to reset button Compress...

Страница 10: ...5 26 5 31 7 40 6 38 8 44 1 63 5 1 Rated Flow Capacity Conditions for rating dryers are in accordance with ISO 7183 Option A2 Compressed air at dryer inlet 100 psig 6 7 barg and 100 F 38 C ambient air...

Страница 11: ...4 28 362 6 12 76 324 21 70 551 2 23 67 601 2 2 16 55 4 38 111 2 2 02 51 2 1 18 30 1 18 30 1 100 2 02 51 2 3 79 96 2 1 96 50 19 26 489 2 2 44 62 32 33 821 2 21 26 540 31 15 791 2 1 18 30 14 28 362 6 12...

Страница 12: ...G H I MODEL DIMENSIONS INCHES MM CONNECTIONS INCHES NPT A B C D E F G H I J K L M N O P Q R 200 2 65 67 2 7 13 181 2 1 96 50 24 38 619 2 3 62 92 36 66 931 2 28 74 730 35 48 901 2 1 18 30 19 39 492 6 1...

Страница 13: ...1 96 50 25 56 649 2 4 41 112 43 75 1111 2 35 83 910 42 57 1081 2 1 18 30 19 39 492 6 17 87 454 29 97 761 2 31 94 811 2 2 36 60 5 95 151 2 3 20 81 2 1 58 40 1 58 30 2 500 2 65 67 2 7 13 181 2 1 96 50...

Страница 14: ...valve timer Customer s installation Ref Compressor M1 C S M R S2 CR SOL1 Electric drain SK1 Spark Killer Resistance 120 Capacitor 0 1uF M1 Ref Compressor GL1 S1 L N S0 S3 L1 N1 T1 SOL1 M2 SK1 2 3 LEG...

Страница 15: ...rain valve timer SOL1 Electric drain SK1 Spark Killer Resistance 120 Capacitor 0 1uF Customer s installation Ref Compressor M1 CS C S M R S2 CR CR Running capacitor GL1 S1 L N S0 M2 S3 L1 N1 T1 SOL1 S...

Страница 16: ...0 M2 L1 N1 T1 SOL1 SK1 S2 2 1 S3 S4 N1 8 7 LEGEND CR Running Capacitor M1 Ref Compressor M2 Fan Motor GL1 Green Lamp CH Crankcase Heater S1 Switch on off S2 Overload Protector S3 Fan Pressure Switch S...

Страница 17: ...GL1 S1 MC1 S4 S3 T2 R2 MC2 TH1 T1 R1 M2 M1 SK1 12 11 COM COMP COMP S1 A2 FG A1 A2 R2 T2 R2 8 FG RCOM RB RA 2 1 8 7 13 LEGEND M1 Ref Compressor M2 Fan Motor MC1 Magnetic Contactor MC2 Magnetic Contact...

Страница 18: ...S4 S3 T2 R2 MC2 TH1 T1 R1 M2 M1 SK1 12 11 COM COMP COMP S1 A2 FG A1 A2 R2 T2 R2 8 FG RCOM RB RA 2 1 8 7 13 LEGEND M1 Ref Compressor M2 Fan Motor MC1 Magnetic Contactor MC2 Magnetic Contactor S1 Switch...

Страница 19: ...MC1 Magnetic Contactor MC2 Magnetic Contactor Ref Compressor Fan Motor TEMP SENSOR Drain valve TB1 TB1 Terminal Block for Main Power Customer s installation L3 L1 E L2 GL1 S1 MC1 S4 S3 T2 R2 MC2 TH1 T...

Страница 20: ...VALVE TEMP SENSOR FOR PANEL DISPLAY TI SCHRADER VALVE REF AIR S WETTED AIR INLET DRIED AIR OUTLET AIR AIR MOISTURE SEPARATOR INTEGRATED STRAINER AUTO DRAIN VALVE DRAIN OUTLET TIMED ELECTRIC BALL VALVE...

Страница 21: ...RGD250A4 RGD300A4 RGD400A4 RGD500A4 1 Refrigerant Compressor G3161251 G3161251 G3093041 G3137014 G3137014 2 Condenser G7433669 G7478057 G7433670 G7433671 G7433672 3 Fan Blades G3041958 4 Fan Motor G7...

Страница 22: ...n valve prefilter element afterfilter element filter drain 2 RGDMKF9 RGDMKF9 RGDMKF10 RGDMKF23 Model Kit Components RGD200A4 RGD250A4 RGD300A4 RGD400A4 RGD500A4 Standard Kit Drain valve G7477982 G7477...

Страница 23: ......

Страница 24: ...rranty claim once submitted Unauthorized service and use of unauthorized or pirated parts voids the warranty and any resulting charges or subsequent claim will not be paid Products repaired or replace...

Отзывы: