24
|
www.gd-elmorietschle.com
© Gardner Denver Schopfheim GmbH
Fig. 7 Change the oil
Maintenance and repair
H
Oil filling point
H
1
Vent screw
I
Oil sight glass
K
Oil discharge point
N
Data plate (recommended type of oil)
N
K
H
I
H
1
H
1
K
H
I
N
7.2.1 Change the oil
CAUTION
Risk of injury due to slipping and falling!
The floor can be slippery due to leaked oil and cause slipping, tripping or falling.
Ø
For oil change wear non-slip shoes.
Ø
Remove leaked oil immediately.
If it is not completely emptied, the refilling quantity is reduced.
If you change the type of oil, empty the oil tank completely.
A minimum oil quantity may escape from the vent screw due to pressure compensation.
If larger quantities of oil escape, wash the internal filter of the vent screw.
The waste oil must be disposed of in compliance with the local environmental protection regulations.
Check the oil level:
a) Check the oil level in the sight glasses (Fig. 7/I) every month.
b) To refill the oil, switch off the machine and bleed to atmospheric pressure.