23
www.gd-elmorietschle.com
© Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH
|
Maintenance and repair
I
K
M
H
7.2.1 Changing the oil
Fig. 6
Change the oil
H
Oil filling point with vent screw
I
Oil sight glass
K
Oil discharge point
M
Oil recommendation plate
Change the oil:
NotiCe
Always change the oil when the machine is at
operating temperature and in an atmospherically
ventilated area.
If it is not completely emptied, the refilling quantity
will be reduced.
The waste oil must be disposed of in compliance
with the local environmental protection regulations.
If you change the type of oil, empty the oil tank
completely.
A minimum oil quantity can get out of the oil filling
point by pressure compensation.
If larger quantities of oil escape, wash the internal
filter of the vent screw.
The oil levels in the sight glasses (Fig. 6/I) must be
checked every month.
To refill the oil level, it is required to switch off the
machine and to bleed it to atmospheric pressure.
Oil change has to be done after 5,000 operating
hours.
The oil viscosity must comply with ISO-VG 150 or
220 as per ISO 3448.
Designation as per DIN 51502: CLP HC 150.
We recommend the following brands of oil: GEAR-
LUBE 150 or GEAR-LUBE 220 (Variant 31+32) or
equivalent oil of other manufacturers (see also oil
recommendation plate (Fig. 6/M)).
Содержание Elmo Rietschle C-VLR 60