16
|
www.gd-elmorietschle.com
© Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH
Installation
5.3 Connecting pipes
a) Vacuum connection at (Fig. 2/A).
b) Connect the vacuum line.
NOTICE
Material damage resulting from the forces and
torques of the pipes on the unit being too high.
Only screw pipes in by hand.
The suction capacity of the vacuum pump is
reduced if the suction pipe is too narrow and/
or too long.
c) The extracted air can be discharged through the
exhaust silencer (Fig. 2/B) or conducted away
via a pipe.
NOTICE
Exhaust air must not be restricted
No blocking systems must be built into the
exhaust air pipe (max. pressure difference 50
mbars). When the exhaust air pipe is connected it
must be checked regularly for impurities.
5.4 Filling with lubricating oil
a) Fill the lubricating oil (for suitable types see
“Maintenance”) for the gear wheels and oil fill-
ing point (Fig. 2/H) up to the middle of the sight
glasses (Fig. 2/I).
b) Close the oil filling point.