13–13–600 Page 48
SYMPTOM
POSSIBLE CAUSE
REMEDY
Oil Carry–Over (Continued)
4.
Loose assembly.
4.
Tighten all fittings and
gaskets.
5.
Foam caused by use of
5.
Use Gardner Denver
R
incorrect oil.
AEON
t
9000 SP
Lubricating Coolant.
6.
Inoperative minimum
6.
Clean out or replace valve.
pressure valve.
7.
Operation at elevated
7.
Reduce temperature. See
discharge temperatures.
High Discharge Air
Temperature, page 47,
this section.
8.
Scavenge line check
8.
Replace check valve.
valve failure.
9.
Water condensate in oil.
9.
Check oil reservoir tempera–
ture and if low, change
thermal mixing valve element
to higher temperature.
Gardner Denver factory remanufactured replacement compressor air end units
are available from your authorized distributor, on an exchange basis, for all rotary
screw compressor units.
Содержание ELECTRA-SAVER ETY99A
Страница 14: ...13 13 600 Page 6 DECALS 206EAQ077 212EAQ077 218EAQ077 211EAQ077 207EAQ077...
Страница 15: ...13 13 600 Page 7 DECALS 216EAQ077 217EAQ077 222EAQ077 221EAQ077 208EAQ077...
Страница 29: ...13 13 600 Page 21 FIGURE 4 1 SCHEMATIC TUBING DIAGRAM 302ETY797 A Ref Drawing...
Страница 34: ...13 13 600 Page 26 FIGURE 4 8 CONTROL SCHEMATIC COMPRESSOR AT FULL LOAD 304ETY797 A Ref Drawing...
Страница 37: ...13 13 600 Page 29 FIGURE 4 11 WIRING DIAGRAM 302ETY546 Ref Drawing...
Страница 39: ...13 13 600 Page 31 FIGURE 5 1 FLOW DIAGRAM 303ETY797 A Ref Drawing...
Страница 58: ...Specifications subject to change without notice Copyright 1998 Gardner Denver Machinery Inc...