ANCILLARY EQUIPMENT
Page 93
ADJUSTING NUT
CONDUIT
THREAD
INSTALLATION
Mount the switch by the bracket provided.
It is usual to connect 1 (C) and 2 (NC) to the compressor electrical control circuit terminals marked
"Pressure Switch".
Remove cover to set pressure setting, using a pressure gauge. Note:- Switches are pre-set and do not
usually need adjusting. Please confirm with Engineering at CompAir UK Ltd Ipswich if switches are to be
adjusted.
a.
Turn adjusting nut clockwise to lower set point.
b.
Turn adjusting nut anti clockwise to raise set point.
c.
To adjust differential use notched wheel below the microswitch.
98407.1039 iss8