3
IMPORTANT:
READ PRIOR TO STARTING THIS EQUIPMENT
1.0 Installation
1.1 Location
A. For typical placement in a compressed air system,
see drawing.
B. Air compressor intake–Locate air compressor so
that contaminants potentially harmful to the
dryer (e.g. ammonia) are not drawn into the air
system.
C. Clearances
Free air flow - Allow at least 12 inches (305 mm) on
the front and each side of the cabinet and 6 inches
(152 mm) at the back of the cabinet for free air flow.
Service - To facilitate maintenance leave 24 inches
(610 mm) of clearance in front of dryer.
D. Standard units are designed to operate in ambients
from 45 to 110
°
F (7 to 43
°
C).
E. Installations in altitudes above 4500 feet (1370 meters)
– Dryer is adjusted to operate in altitudes up to 4500
feet (1370 meters). If dryer is installed in an altitude
above this, and has not been preset at the factory for
this altitude, contact manufacturer’s Service Depart-
ment.
NOTE: Outdoor installation–Standard units are designed
for indoor installation. Contact manufacturer if installing
outdoors.
1.2 Mounting
Mount on floor or shelf free from vibration.
Aftercooler
Separator
Dryer
Oil Removal
Filter
Compressor
Power Cord
Air Inlet
Air Outlet
Quick Release
Locks
Air Flow
* Screws used for shipping only.
Remove after installation.
Separator
Temperature
Indicator
Power On
Light
On/Off Switch
Drain
Condenser