![Gardner Denver 4500 Series Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/gardner-denver/4500-series/4500-series_parts-list-operating-and-service-manual_3558903011.webp)
SB--7--626 Page 2
SECTION 1
EQUIPMENT CHECK
Before uncrating, check the packing slip carefully to be
sure all the parts have been received. All accessories
are listed as separate items on the packing slip, and
small important accessories such as relief valves can
be overlooked or lost. After every item on the packing
slip has been checked off, uncrate carefully. Register
a claim with the carrier for lost or damaged equipment.
Customers are cautioned to provide
adequate protection, warning and
safety equipment necessary to protect
personnel against hazards involved in
installation and operation of this
equipment in the system or facility.
STORAGE
Your Sutorbilt Blower was packaged at the factory with
adequate protection to permit normal storage for up to
six (6) months.
If the unit is to be stored under adverse conditions or
for extended periods of time, the following additional
measures should be taken to prevent damage.
1.
Store the blower in a clean, dry, heated area.
2.
Make certain inlet and discharge air ports are
tightly covered to prevent foreign material from
entering the air box.
3.
All exposed, non--painted surfaces should be
protected against rust and corrosion.
4.
Provide adequate protection to avoid accidental
mechanical damage.
5.
In high humidity or corrosive environments,
additional measures may be required to prevent
rusting of the blower internal surfaces.
6.
To prevent rusting of gears, bearings, etc., the oil
reservoirs may be filled with normal operating oil.
Before running the blower, drain the
oil and replace to the proper operat-
ing level with clean, fresh lubricant.
7.
Rotate the blower shaft (10 to 25 turns) weekly
during storage. Inspect the blower shaft (near the
shaft seal area) monthly and spray with rust
inhibitor if needed.
8.
For long term storage (over six (6) months),
contact Sutorbilt Customer Service for recom-
mendations.
REMOVING PROTECTIVE MATERIALS
Blower inlet and outlet are temporarily capped to keep
out dirt and other contaminants during shipment.
These covers must be removed before start--up.
RUST INHIBITIVE COATING
The internal surface of all Sutorbilt units are mist
sprayed with a rust inhibitive to protect the machine
during shipment.
Rotating components will cause
severe injury in case of personal
contact.
Keep hands away from
blower inlet and discharge ports.