2.1 For Your Safety

1) Use extreme caution when checking electrical circuits.

2)

Do not stand in wet or damp work areas when

working with electricity. Wear rubber-soled boots or shoes.

3)

Do not apply more voltage or current than

the set range of the multimeter will allow.

4)

Do not touch the metal probes of the test

leads when making a measurement.

5) Replace worn test leads. Do not use test leads with broken

or tattered insulation.

6) Discharge a capacitor before measuring it.

7) Remove the test leads from the circuit being measured as

soon as the test is completed.

8)

Do not measure voltage when the

function/range switch is set on the resistance (ohms) or the
current (mA) settings. Never measure current when the meter
is set on the resistance range. Never measure AC voltage
when the meter is set on DC voltage or DCmA. Setting the
meter on the incorrect function may burn out some of the
internal circuitry and may pose a safety hazard.

3. Operating Suggestions

1) Set the function/range switch to the proper position before

making a measurement. When the voltage or current is not
known, it MUST be determined that the capacity of the
selected range will handle the amount of voltage or current
in the circuit (see #3 under For Your Safety). Always start
with the highest range in the function. If the reading falls
within the range of a lower setting, reset the function/range
switch to the appropriate setting for greater accuracy.

2) Avoid placing the meter in areas where vibration, dust or dirt

are present. Do not store the meter in excessively hot,
humid or damp places. This meter is a sensitive measuring
device and should be treated with the same regard as other
electrical and electronic devices.

3) Using the meter in areas with high magnetic fields can result

in inaccurate readings. For greatest accuracy, lay the meter
flat on a non-metallic surface.

4

!

WARNING

!

WARNING

!

WARNING

!

WARNING

2. Specifications

Ranges: 

12 measuring ranges

DC Voltage: 

10-50-250-500 Volts

AC Voltage: 

10-50-250-500 Volts

DC Current (Milliamperes): 

0.5-50-250mA

Resistance (Ohms):

Rx1K (resistance indicated multiplied by 1000) 
1 Megohm max

Decibels: 

-20dB to +56dB on AC voltage ranges

Accuracy: 

DC voltage, mA = 4% full scale of range
AC voltage = 5% full scale of range
Resistance = 4° arc of scale length

Sensitivity: 

2000 ohms per volt DC and AC

Function/Range Switch: 

5 functions
13 positions
12 measuring ranges

Zero Ohms Adjustment Dial:  Located on the left side of the housing; adjustment

dial is used to zero the needle indicator on the 
ohms scale while shorting the test leads together.

Mechanical Zero 
Adjustment Screw:

Located directly below the center of the meter 
scale; adjust needle indicator to read zero 
at the left side of the scale before taking 
any measurement.

Mirrored Scale Plate: 

The mirror on the scale plate is used to line up the 
needle with its reflection to improve the reading 
accuracy by preventing parallax error.

Recessed Input Jacks: 

Negative (-) input jack for black test lead, positive 
(+) input jack for red test lead.

Important:

Read this operators manual thoroughly before using this
multimeter. This manual is intended to provide basic
information regarding this multimeter and to describe 
common test procedures which can be made with this unit.
Many types of appliance, machinery and other electrical 
circuit measurements are not addressed in this manual 
and should be handled by experienced service technicians.

Use extreme caution when using this

multimeter. Improper use of this meter can result in
severe damage to property, severe personal injury or
death. Follow all instructions and suggestions in this
operators manual as well as normal electrical safety
precautions. Do not use this multimeter if you are
unfamiliar with electrical circuits and proper 
test procedures. 

3

!

WARNING

Содержание GMT-12A

Страница 1: ...ique Manuel d utilisation Read this owners manual thoroughly before use and save Lea completamente este manual del propietario antes del uso y cons rvelo como referencia Avant de se servir du multimet...

Страница 2: ...cks Function Range Selector Switch Contents 1 Meter Functions 2 Specifications 2 1 For Your Safety 3 Operating Suggestions 3 1 Preliminary Adjustments 3 2 Internal Battery Condition 4 DC Voltage Measu...

Страница 3: ...s For greatest accuracy lay the meter flat on a non metallic surface 4 WARNING WARNING WARNING WARNING 2 Specifications Ranges 12 measuring ranges DC Voltage 10 50 250 500 Volts AC Voltage 10 50 250 5...

Страница 4: ...ent 1 Fully seat the test leads in the correct input jacks black lead red lead 5 4 When the meter is not in use keep the function range switch in the OFF position This keeps the needle indicator from...

Страница 5: ...gnificantly low the alternator may require service or replacement When making automotive measurements observe safety precautions Stay away from the fan blades belts and other moving parts of the engin...

Страница 6: ...ndicate 120V AC when one test lead contacts the hot side of the receptacle If ground 10 4 3 Household Batteries Set the function range switch to 10V DC to test household 1 5 volt through 9 volt batter...

Страница 7: ...s Common Resistance and Continuity Measurements Continuity tests are probably the most frequently performed electrical troubleshooting procedures around the home ALWAYS REMEMBER THAT CONTINUITY CHECKS...

Страница 8: ...test leads to one of the metal prong ends of the cord and insert the other test lead in either one of the receptacle slots on the other end of the cord making sure the test lead is making good contact...

Страница 9: ...confused with audio decibels This function is used primarily by electronics technicians to measure the power gain in transistors and is rarely encountered in home project applications 1 Fully seat the...

Страница 10: ...interna 4 Medici n de voltaje DC 4 1 Bater as automotrices 4 2 Alternadores y generadores 4 3 Bater as pilas dom sticas 5 Medici n de corriente continua mA 6 Medici n de voltaje AC 6 1 Recept culos de...

Страница 11: ...ECAUCION 19 2 Especificaciones Escalas 12 escalas de medici n Voltaje DC 10 50 250 500 voltios Voltaje AC 10 50 250 500 voltios Corriente DC miliamperios 0 5 50 250mA Resistencia ohmios Rx1K resistenc...

Страница 12: ...lientes o h medos Este probador es un dispositivo de medici n sensible y debe ser tratado con el mismo cuidado que otros dispositivos el ctricos y electr nicos 3 Utilizar el probador en zonas con camp...

Страница 13: ...lado derecho de la escala para la conversi n correcta 3 2 Estado de la bater a interna Antes de efectuar las pruebas de resistencia o continuidad revise el estado de la bater a interna Primero coloque...

Страница 14: ...ra 4 el conductor de prueba rojo est conectado al terminal de la bater a de la linterna mientras que el conductor de prueba negro est conectado al bulbo El probador indicar el consumo de corriente en...

Страница 15: ...ductor de prueba de la misma forma que antes La lectura del probador debe ser de 120 voltios AC con un conductor de prueba tocando la caja el ctrica y el otro tocando el lado vivo del recept culo De l...

Страница 16: ...as ranuras del recept culo en el otro extremo del cable asegur ndose de que el conductor de prueba haga buen contacto con el recept culo vea la fig 9 Si la aguja no se mueve a 0 ohmios introduzca el c...

Страница 17: ...l fusible En los fusibles de tipo tap n toque uno de los conductores de prueba con el contacto inferior y el otro conductor de prueba con el contacto met lico roscado vea la fig 11 En los fusibles de...

Страница 18: ...de decibeles la impedancia del circuito debe ser al menos de 600 ohmios 0 decibeles 1 milivatio en una impedancia de 600 ohmios equivalente a 0 775 voltios 600 ohmios 9 Reemplazo de la bater a y del f...

Страница 19: ...t de la pile interne 4 Mesure de tension c c 4 1 Batteries automobiles 4 2 Alternateurs et dynamos 4 3 Piles d usage domestique 5 Mesure d intensit c c mA 6 Mesures de tension c a 6 1 Prises murales 6...

Страница 20: ...uel d utilisation et prendre toutes les pr cautions normales concernant l lectricit Ne pas utiliser ce multim tre sans tre familiaris avec les circuits lectriques et les m thodes de test appropri es 2...

Страница 21: ...n cessaire tourner lentement la vis de r glage m canique dans un sens ou dans l autre de fa on placer l aiguille exactement au dessus des trois z ros noirs de l extr mit gauche de l chelle Multim tre...

Страница 22: ...ion c c 10 0 10 1 50 0 50 1 250 0 250 1 500 0 50 10 Mesures courantes de tension c c 4 1 Batteries automobiles Mettre le s lecteur fonctions gammes sur 50 DC V V rifier d abord la qualit de la connexi...

Страница 23: ...e d intensit c c mA 1 Ins rer les connecteurs des fils de sonde fond dans les jacks d entr e appropri s 2 Mettre le s lecteur fonctions gammes sur la position 250 DC mA 3 Brancher les sondes d essai e...

Страница 24: ...se la terre des prises non polaris es fig 6 mettre les sondes d essai alternativement en contact entre les fentes de la prise et la vis de la plaque murale Le multim tre doit indiquer 120 V c a lorsqu...

Страница 25: ...r les contr les de continuit la polarit des sondes d essai n entre pas en ligne de compte 7 1 Rallonges D brancher la rallonge Mettre le s lecteur fonctions gammes sur la gamme d ohms X1K Mettre une d...

Страница 26: ...des extr mit s de l l ment et noter l indication de l aiguille Elle doit correspondre une r sistance faible Si l aiguille reste immobile l l ment chauffant est bris Si la continuit existe dans les l m...

Страница 27: ...ectrical Testing and Troubleshooting Comment utiliser le multim tre pour le contr le et le d pannage d appareils lectriques Disponible uniquement en anglais Ce guide d utilisation de multim tres analo...

Страница 28: ...Gardner Bender www gardnerbender com PO Box 3241 Milwaukee WI 53201 3241 414 352 4160 6615 Ordan Drive Mississauga Ontario L5T 1X2 905 564 5749 ZX000132 Rev A...

Отзывы: