WARNING

F. Measuring AC Current (See Figure 8)

To avoid electric shock, never measure current while the test leads are inserted into the input terminals and disconnect test leads and 

tested circuit connections. Never attempt an in-circuit current measurement where the open-circuit voltage between the circuit and the 

ground is greater than 600V. Use proper function and range for any measurements. 

To measure current, do the following:
1. Set the rotary switch to 20A

~

, 200 A

~

 or 600 A

~

2. Press the trigger to open the transformer jaws.
3. Center the conductor within the transformer jaw, then release the Meter slowly until the 

transformer jaw is completely closed, Make sure the conductor to be tested is placed at the 

center of the transformer jaw, otherwise it will cause deviation. The Meter can only measure one 

conductor at a time, to measure more than one conductor at a time will cause deviation.

NOTE:

When current measurement has been completed,disconnect the  

connection between the conductor under test and the jaw, and  

remove the conductor away from the transformer jaw of the Meter.

Figure 3

Figure 2

Figure 4

Figure 5

Figure 6

Figure 7

Figure 8

 Figure 9

Figure 7

VI. ACCURACY SPECIFICATIONS

Accuracy: ±(a% r b digits), guarantee for 1 year.
Operating temperature: 23˚C±5˚C
Relative humidity: 

75%R.H

Temperature coefficient: 0.1×(specified accuracy) /1˚C

International Electrical Symbols

            AC (Alternating Current)
            DC (Direct Current)
            Grounding
            Double Insulated
            Warning. Refer to the Operating Manual
            Low Battery Indication
            Continuity Test
            Diode
            Conforms to Standards of European Union

Number   

Description

  1          Indicator for AC voltage or current
  2          Indicator for DC voltage 
  3          The battery is low.
          Warning: To avoid false readings, which 

 could lead to possible electric shock or 

 personal injury, replace the battery as soon as 

 the battery indicator appears. 
  4         The Meter is in the auto range mode in 

             which the Meter automatically selects 

             the range with the best resolution.
  5         Test of diode
  6         The continuity buzzer is on
  7         Maximum reading displayed
  8         Data hold is active
  9         Amperes (amps). The unit of current.
  10       Ω: Ohm. The unit of resistance.

             kΩ:Kilohm.  1000 ohms

             MΩ:Megohm. 1,000,000 ohms
  11       V:  Volts. The unit of voltage.
             mV: Millivolt.  0.001 volts
  12       Indicates negative reading

 

 Rotary               Functional Buttons

 Switch      

SELECT        MAX        HOLD 

 Positions

 Ω                    • 

           N/A 

    

       N/A                •  

   

       N/A                •  

 A    20A         N/A                •  

 A    200A        N/A                •  

 A    600A        N/A                •                 •

A.  AC Voltage: Auto Ranging

 Range  Resolution 

Accuracy 

 2.000V     1mV 

               

 20.00V     10mV                  ±(1.2%+5)
 200.0V     100mV   
 600V 

    1V 

                ±(1.5%+5)

B. DC Voltage: Auto Ranging

 Range   Resolution 

Accuracy 

 200.0mV    0.1mV                  ±(0.8%+3)
 2.000V     1mV 

             

 20.00V     10mV                  ±(0.8%+1)
 200.0V     100mV   
 600V 

   1V 

                ±(1%+3) 

Remarks: 

●    Input impedance: 10MΩ

●    Overload protection: 600V rms

C.  Resistance: Auto Ranging

 Range      Resolution 

Accuracy 

 200.0Ω         100mΩ 

±(1.2%+2)

 2.000kΩ        1Ω                  
 20.00kΩ        10Ω   

±(1%+2)

 200.0kΩ        100Ω   
 2.000MΩ       1kΩ                 ±(1.2%+2) 
 20.00MΩ        10kΩ                ±(1.5%+2)
Remark: 

●    Overload protection: 600Vp

D. Continuity 

 Range   Resolution              Accuracy 
  

  

        Around <10Ω,the 

                                        buzzer beeps.
Remark:

●    Overload Protection: 600Vp

●    Open circuit voltage approximate 0.45V.

●    The buzzer may or may not beeps when the 

      resistance of a circuit under test is more 

      than 10Ω.

E.  Diode 

 Range  Resolution 

Accuracy 

                    

         Display approximate 

                                          forward voltage drop
Remarks: 

●    Overload Protection:  600Vp

●    Open circuit voltage approximate 1.48V.

  

1mV

100mΩ 

F.  AC Current: Auto Ranging

 Range          Resolution          Accuracy 
 20.00A         0.01A                ±(2.0%+5)
 200.0A          0.1A  

±(1.5%+5) 

  600A 

        1A                  ±(2.0%+8)

Remarks:

Remarks:

• Overload protection:600V rms
• Input impedance: 10M

Ω

 // <100pF

•  Displays RMS value of sine wave  

(mean value response).

• Frequency response: 40Hz~400Hz.

International Electrical Symbols

            AC (Alternating Current)
            DC (Direct Current)
            Grounding
            Double Insulated
            Warning. Refer to the Operating Manual
            Low Battery Indication
            Continuity Test
            Diode
            Conforms to Standards of European Union

Number   

Description

  1          Indicator for AC voltage or current
  2          Indicator for DC voltage 
  3          The battery is low.
          Warning: To avoid false readings, which 

 could lead to possible electric shock or 

 personal injury, replace the battery as soon as 

 the battery indicator appears. 
  4         The Meter is in the auto range mode in 

             which the Meter automatically selects 

             the range with the best resolution.
  5         Test of diode
  6         The continuity buzzer is on
  7         Maximum reading displayed
  8         Data hold is active
  9         Amperes (amps). The unit of current.
  10       Ω: Ohm. The unit of resistance.

             kΩ:Kilohm.  1000 ohms

             MΩ:Megohm. 1,000,000 ohms
  11       V:  Volts. The unit of voltage.
             mV: Millivolt.  0.001 volts
  12       Indicates negative reading

 

 Rotary               Functional Buttons

 Switch      

SELECT        MAX        HOLD 

 Positions

 Ω                    • 

           N/A 

    

       N/A                •  

   

       N/A                •  

 A    20A         N/A                •  

 A    200A        N/A                •  

 A    600A        N/A                •                 •

A.  AC Voltage: Auto Ranging

 Range  Resolution 

Accuracy 

 2.000V     1mV 

               

 20.00V     10mV                  ±(1.2%+5)
 200.0V     100mV   
 600V 

    1V 

                ±(1.5%+5)

B. DC Voltage: Auto Ranging

 Range   Resolution 

Accuracy 

 200.0mV    0.1mV                  ±(0.8%+3)
 2.000V     1mV 

             

 20.00V     10mV                  ±(0.8%+1)
 200.0V     100mV   
 600V 

   1V 

                ±(1%+3) 

Remarks: 

●    Input impedance: 10MΩ

●    Overload protection: 600V rms

C.  Resistance: Auto Ranging

 Range      Resolution 

Accuracy 

 200.0Ω         100mΩ 

±(1.2%+2)

 2.000kΩ        1Ω                  
 20.00kΩ        10Ω   

±(1%+2)

 200.0kΩ        100Ω   
 2.000MΩ       1kΩ                 ±(1.2%+2) 
 20.00MΩ        10kΩ                ±(1.5%+2)
Remark: 

●    Overload protection: 600Vp

D. Continuity 

 Range   Resolution              Accuracy 
  

  

        Around <10Ω,the 

                                        buzzer beeps.
Remark:

●    Overload Protection: 600Vp

●    Open circuit voltage approximate 0.45V.

●    The buzzer may or may not beeps when the 

      resistance of a circuit under test is more 

      than 10Ω.

E.  Diode 

 Range  Resolution 

Accuracy 

                    

         Display approximate 

                                          forward voltage drop
Remarks: 

●    Overload Protection:  600Vp

●    Open circuit voltage approximate 1.48V.

  

1mV

100mΩ 

F.  AC Current: Auto Ranging

 Range          Resolution          Accuracy 
 20.00A         0.01A                ±(2.0%+5)
 200.0A          0.1A  

±(1.5%+5) 

  600A 

        1A                  ±(2.0%+8)

Remarks:

Remarks:

• Input impedance: 10M

Ω

• Overload protection: 600V rms

Remarks:

• Overload protection: 600Vp

International Electrical Symbols

            AC (Alternating Current)
            DC (Direct Current)
            Grounding
            Double Insulated
            Warning. Refer to the Operating Manual
            Low Battery Indication
            Continuity Test
            Diode
            Conforms to Standards of European Union

Number   

Description

  1          Indicator for AC voltage or current
  2          Indicator for DC voltage 
  3          The battery is low.
          Warning: To avoid false readings, which 

 could lead to possible electric shock or 

 personal injury, replace the battery as soon as 

 the battery indicator appears. 
  4         The Meter is in the auto range mode in 

             which the Meter automatically selects 

             the range with the best resolution.
  5         Test of diode
  6         The continuity buzzer is on
  7         Maximum reading displayed
  8         Data hold is active
  9         Amperes (amps). The unit of current.
  10       Ω: Ohm. The unit of resistance.

             kΩ:Kilohm.  1000 ohms

             MΩ:Megohm. 1,000,000 ohms
  11       V:  Volts. The unit of voltage.
             mV: Millivolt.  0.001 volts
  12       Indicates negative reading

 

 Rotary               Functional Buttons

 Switch      

SELECT        MAX        HOLD 

 Positions

 Ω                    • 

           N/A 

    

       N/A                •  

   

       N/A                •  

 A    20A         N/A                •  

 A    200A        N/A                •  

 A    600A        N/A                •                 •

A.  AC Voltage: Auto Ranging

 Range  Resolution 

Accuracy 

 2.000V     1mV 

               

 20.00V     10mV                  ±(1.2%+5)
 200.0V     100mV   
 600V 

    1V 

                ±(1.5%+5)

B. DC Voltage: Auto Ranging

 Range   Resolution 

Accuracy 

 200.0mV    0.1mV                  ±(0.8%+3)
 2.000V     1mV 

             

 20.00V     10mV                  ±(0.8%+1)
 200.0V     100mV   
 600V 

   1V 

                ±(1%+3) 

Remarks: 

●    Input impedance: 10MΩ

●    Overload protection: 600V rms

C.  Resistance: Auto Ranging

 Range      Resolution 

Accuracy 

 200.0Ω         100mΩ 

±(1.2%+2)

 2.000kΩ        1Ω                  
 20.00kΩ        10Ω   

±(1%+2)

 200.0kΩ        100Ω   
 2.000MΩ       1kΩ                 ±(1.2%+2) 
 20.00MΩ        10kΩ                ±(1.5%+2)
Remark: 

●    Overload protection: 600Vp

D. Continuity 

 Range   Resolution              Accuracy 
  

  

        Around <10Ω,the 

                                        buzzer beeps.
Remark:

●    Overload Protection: 600Vp

●    Open circuit voltage approximate 0.45V.

●    The buzzer may or may not beeps when the 

      resistance of a circuit under test is more 

      than 10Ω.

E.  Diode 

 Range  Resolution 

Accuracy 

                    

         Display approximate 

                                          forward voltage drop
Remarks: 

●    Overload Protection:  600Vp

●    Open circuit voltage approximate 1.48V.

  

1mV

100mΩ 

F.  AC Current: Auto Ranging

 Range          Resolution          Accuracy 
 20.00A         0.01A                ±(2.0%+5)
 200.0A          0.1A  

±(1.5%+5) 

  600A 

        1A                  ±(2.0%+8)

Remarks:

Remarks:

• Overload Protection: 600Vp
• Open circuit voltage approximate 0.45V.
•  The buzzer may or may not beeps when 

the resistance of a circuit under test is 

more than 10

Ω

.

International Electrical Symbols

            AC (Alternating Current)
            DC (Direct Current)
            Grounding
            Double Insulated
            Warning. Refer to the Operating Manual
            Low Battery Indication
            Continuity Test
            Diode
            Conforms to Standards of European Union

Number   

Description

  1          Indicator for AC voltage or current
  2          Indicator for DC voltage 
  3          The battery is low.
          Warning: To avoid false readings, which 

 could lead to possible electric shock or 

 personal injury, replace the battery as soon as 

 the battery indicator appears. 
  4         The Meter is in the auto range mode in 

             which the Meter automatically selects 

             the range with the best resolution.
  5         Test of diode
  6         The continuity buzzer is on
  7         Maximum reading displayed
  8         Data hold is active
  9         Amperes (amps). The unit of current.
  10       Ω: Ohm. The unit of resistance.

             kΩ:Kilohm.  1000 ohms

             MΩ:Megohm. 1,000,000 ohms
  11       V:  Volts. The unit of voltage.
             mV: Millivolt.  0.001 volts
  12       Indicates negative reading

 

 Rotary               Functional Buttons

 Switch      

SELECT        MAX        HOLD 

 Positions

 Ω                    • 

           N/A 

    

       N/A                •  

   

       N/A                •  

 A    20A         N/A                •  

 A    200A        N/A                •  

 A    600A        N/A                •                 •

A.  AC Voltage: Auto Ranging

 Range  Resolution 

Accuracy 

 2.000V     1mV 

               

 20.00V     10mV                  ±(1.2%+5)
 200.0V     100mV   
 600V 

    1V 

                ±(1.5%+5)

B. DC Voltage: Auto Ranging

 Range   Resolution 

Accuracy 

 200.0mV    0.1mV                  ±(0.8%+3)
 2.000V     1mV 

             

 20.00V     10mV                  ±(0.8%+1)
 200.0V     100mV   
 600V 

   1V 

                ±(1%+3) 

Remarks: 

●    Input impedance: 10MΩ

●    Overload protection: 600V rms

C.  Resistance: Auto Ranging

 Range      Resolution 

Accuracy 

 200.0Ω         100mΩ 

±(1.2%+2)

 2.000kΩ        1Ω                  
 20.00kΩ        10Ω   

±(1%+2)

 200.0kΩ        100Ω   
 2.000MΩ       1kΩ                 ±(1.2%+2) 
 20.00MΩ        10kΩ                ±(1.5%+2)
Remark: 

●    Overload protection: 600Vp

D. Continuity 

 Range   Resolution              Accuracy 
  

  

        Around <10Ω,the 

                                        buzzer beeps.
Remark:

●    Overload Protection: 600Vp

●    Open circuit voltage approximate 0.45V.

●    The buzzer may or may not beeps when the 

      resistance of a circuit under test is more 

      than 10Ω.

E.  Diode 

 Range  Resolution 

Accuracy 

                    

         Display approximate 

                                          forward voltage drop
Remarks: 

●    Overload Protection:  600Vp

●    Open circuit voltage approximate 1.48V.

  

1mV

100mΩ 

F.  AC Current: Auto Ranging

 Range          Resolution          Accuracy 
 20.00A         0.01A                ±(2.0%+5)
 200.0A          0.1A  

±(1.5%+5) 

  600A 

        1A                  ±(2.0%+8)

Remarks:

Remarks:

•  Overload Protection: 600Vp
•  Open circuit voltage approximate 1.48V.

International Electrical Symbols

            AC (Alternating Current)
            DC (Direct Current)
            Grounding
            Double Insulated
            Warning. Refer to the Operating Manual
            Low Battery Indication
            Continuity Test
            Diode
            Conforms to Standards of European Union

Number   

Description

  1          Indicator for AC voltage or current
  2          Indicator for DC voltage 
  3          The battery is low.
          Warning: To avoid false readings, which 

 could lead to possible electric shock or 

 personal injury, replace the battery as soon as 

 the battery indicator appears. 
  4         The Meter is in the auto range mode in 

             which the Meter automatically selects 

             the range with the best resolution.
  5         Test of diode
  6         The continuity buzzer is on
  7         Maximum reading displayed
  8         Data hold is active
  9         Amperes (amps). The unit of current.
  10       Ω: Ohm. The unit of resistance.

             kΩ:Kilohm.  1000 ohms

             MΩ:Megohm. 1,000,000 ohms
  11       V:  Volts. The unit of voltage.
             mV: Millivolt.  0.001 volts
  12       Indicates negative reading

 

 Rotary               Functional Buttons

 Switch      

SELECT        MAX        HOLD 

 Positions

 Ω                    • 

           N/A 

    

       N/A                •  

   

       N/A                •  

 A    20A         N/A                •  

 A    200A        N/A                •  

 A    600A        N/A                •                 •

A.  AC Voltage: Auto Ranging

 Range  Resolution 

Accuracy 

 2.000V     1mV 

               

 20.00V     10mV                  ±(1.2%+5)
 200.0V     100mV   
 600V 

    1V 

                ±(1.5%+5)

B. DC Voltage: Auto Ranging

 Range   Resolution 

Accuracy 

 200.0mV    0.1mV                  ±(0.8%+3)
 2.000V     1mV 

             

 20.00V     10mV                  ±(0.8%+1)
 200.0V     100mV   
 600V 

   1V 

                ±(1%+3) 

Remarks: 

●    Input impedance: 10MΩ

●    Overload protection: 600V rms

C.  Resistance: Auto Ranging

 Range      Resolution 

Accuracy 

 200.0Ω         100mΩ 

±(1.2%+2)

 2.000kΩ        1Ω                  
 20.00kΩ        10Ω   

±(1%+2)

 200.0kΩ        100Ω   
 2.000MΩ       1kΩ                 ±(1.2%+2) 
 20.00MΩ        10kΩ                ±(1.5%+2)
Remark: 

●    Overload protection: 600Vp

D. Continuity 

 Range   Resolution              Accuracy 
  

  

        Around <10Ω,the 

                                        buzzer beeps.
Remark:

●    Overload Protection: 600Vp

●    Open circuit voltage approximate 0.45V.

●    The buzzer may or may not beeps when the 

      resistance of a circuit under test is more 

      than 10Ω.

E.  Diode 

 Range  Resolution 

Accuracy 

                    

         Display approximate 

                                          forward voltage drop
Remarks: 

●    Overload Protection:  600Vp

●    Open circuit voltage approximate 1.48V.

  

1mV

100mΩ 

F.  AC Current: Auto Ranging

 Range          Resolution          Accuracy 
 20.00A         0.01A                ±(2.0%+5)
 200.0A          0.1A  

±(1.5%+5) 

  600A 

        1A                  ±(2.0%+8)

Remarks:

Remarks:

• Overload protection: 600A rms
• Frequency Response: 50Hz~60Hz
•  Displays RMS value of sine wave  

(mean value response).

•  To adjust reading in accordance  

with RMS value.

International Electrical Symbols

            AC (Alternating Current)
            DC (Direct Current)
            Grounding
            Double Insulated
            Warning. Refer to the Operating Manual
            Low Battery Indication
            Continuity Test
            Diode
            Conforms to Standards of European Union

Number   

Description

  1          Indicator for AC voltage or current
  2          Indicator for DC voltage 
  3          The battery is low.
          Warning: To avoid false readings, which 

 could lead to possible electric shock or 

 personal injury, replace the battery as soon as 

 the battery indicator appears. 
  4         The Meter is in the auto range mode in 

             which the Meter automatically selects 

             the range with the best resolution.
  5         Test of diode
  6         The continuity buzzer is on
  7         Maximum reading displayed
  8         Data hold is active
  9         Amperes (amps). The unit of current.
  10       Ω: Ohm. The unit of resistance.

             kΩ:Kilohm.  1000 ohms

             MΩ:Megohm. 1,000,000 ohms
  11       V:  Volts. The unit of voltage.
             mV: Millivolt.  0.001 volts
  12       Indicates negative reading

 

 Rotary               Functional Buttons

 Switch      

SELECT        MAX        HOLD 

 Positions

 Ω                    • 

           N/A 

    

       N/A                •  

   

       N/A                •  

 A    20A         N/A                •  

 A    200A        N/A                •  

 A    600A        N/A                •                 •

A.  AC Voltage: Auto Ranging

 Range  Resolution 

Accuracy 

 2.000V     1mV 

               

 20.00V     10mV                  ±(1.2%+5)
 200.0V     100mV   
 600V 

    1V 

                ±(1.5%+5)

B. DC Voltage: Auto Ranging

 Range   Resolution 

Accuracy 

 200.0mV    0.1mV                  ±(0.8%+3)
 2.000V     1mV 

             

 20.00V     10mV                  ±(0.8%+1)
 200.0V     100mV   
 600V 

   1V 

                ±(1%+3) 

Remarks: 

●    Input impedance: 10MΩ

●    Overload protection: 600V rms

C.  Resistance: Auto Ranging

 Range      Resolution 

Accuracy 

 200.0Ω         100mΩ 

±(1.2%+2)

 2.000kΩ        1Ω                  
 20.00kΩ        10Ω   

±(1%+2)

 200.0kΩ        100Ω   
 2.000MΩ       1kΩ                 ±(1.2%+2) 
 20.00MΩ        10kΩ                ±(1.5%+2)
Remark: 

●    Overload protection: 600Vp

D. Continuity 

 Range   Resolution              Accuracy 
  

  

        Around <10Ω,the 

                                        buzzer beeps.
Remark:

●    Overload Protection: 600Vp

●    Open circuit voltage approximate 0.45V.

●    The buzzer may or may not beeps when the 

      resistance of a circuit under test is more 

      than 10Ω.

E.  Diode 

 Range  Resolution 

Accuracy 

                    

         Display approximate 

                                          forward voltage drop
Remarks: 

●    Overload Protection:  600Vp

●    Open circuit voltage approximate 1.48V.

  

1mV

100mΩ 

F.  AC Current: Auto Ranging

 Range          Resolution          Accuracy 
 20.00A         0.01A                ±(2.0%+5)
 200.0A          0.1A  

±(1.5%+5) 

  600A 

        1A                  ±(2.0%+8)

Remarks:

WARNING

VII. MAINTENANCE

This section provides basic maintenance information including battery replacement instruction. 

Do not attempt to repair or service your Meter unless you are qualified to do so and have the relevant calibration,  

performance test, and service information. 

To avoid electrical shock or damage to the Meter, do not get water inside the case.

A. General Service
• Periodically wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents.
• Clean the terminals with a cotton swab with mild detergent. Dirt and Moisture in the terminals can affect the readings of the Meter.
• Turn the Meter power off when it is not in use.
• Remove the battery when the unit is not in use for a long time. 
• Do not use or store the Meter in a place of humidity, high temperature, explosive, inflammable or strong magnetic field.

Содержание GCM-221

Страница 1: ...m 1000 ohms M Megohm 1 000 000 ohms 11 V Volts The unit of voltage mV Millivolt 0 001 volts 12 Indicates negative reading Rotary Functional Buttons Switch SELECT MAX HOLD Positions N A N A N A A 20A N...

Страница 2: ...ircuit during a test If equipment under test has exposed conductive parts extra precaution should be taken to minimize the possibility of shorting Never use the instrument if its surface or your hand...

Страница 3: ...Caution risk of electric shock AC Alternating Current DC Direct current AC DC Selectable Alternating Current Direct Current Earth ground Terminal The equipment is protected throughout by double insul...

Страница 4: ...Auto Ranging Range Resolution Accuracy 200 0 100m 1 2 2 2 000k 1 20 00k 10 1 2 200 0k 100 2 000M 1k 1 2 2 20 00M 10k 1 5 2 Remark Overload protection 600Vp D Continuity Range Resolution Accuracy Aroun...

Страница 5: ...avoid false readings which could lead to possible electric shock or personal injury replace the battery as soon as the battery indicator appears 4 The Meter is in the auto range mode in which the Mete...

Страница 6: ...ay approximate forward voltage drop Remarks Overload Protection 600Vp Open circuit voltage approximate 1 48V 1mV 100m F AC Current Auto Ranging Range Resolution Accuracy 20 00A 0 01A 2 0 5 200 0A 0 1A...

Страница 7: ...ip of product No warranty will be honored unless an invoice or other proof of purchase date is provided to Gardner Bender Hand written receipts or invoices will not be honored 2016 Product Power LLC A...

Отзывы: