stand (1) in a dry and weather protected area.
4.3 Reset Button
1. During operation, if the pump goes into overload ( where there is
a blockage, or impurities have entered the pump filter vents, or the
impeller operation is impeded) the pump will automatically stop and
the re-set button on the battery stand (1) will activate and pop up.
2. If this occurs, the impurity or blockage needs to be removed.
3. First remove the battery (11) from the battery stand (1) so there is no
power to the unit.
4. Check the filter (3) /vents. Remove / clear any obstruction. (See Fig
F1)
5. If the blockage is not in the filter, then the blade needs to be
checked. Unscrew the three screws (using a philips head screwdriver
- not supplied) and remove the filter to check the impeller. Remove /
clear any obstruction. (See Fig F2)
6. Re-assemble the filter.
7. Insert the battery (11) into the battery stand (1) and press the
re-set button (6). If the blockage has been removed, the pump
will commence operation. If this does not occur and pump is not
functioning, please seek further advise from Customer Service on
1300 889 028. (See Fig F3)
NOTE: Don' t remove the other parts except the filter.