background image

After Sales Support     TEL: 1300 130 579     WEB: www.rossmac.com

4

Before you put the dirty water pump into operation,
carefully read the following safety regulations and the
operating instructions.
If you give the equipment to any other persons, give
them the operating instructions as well.

Keep these instructions in a safe place.

Packaging

The unit is supplied in packaging to prevent it from
being damaged in transit. The raw materials in this
packaging can be reused or recycled.

1. Safety instructions

Caution! 

In stagnant water bodies, garden ponds,
swimming ponds and their surrounding areas the
pump may only be used with an earth-leakage
circuit breaker with an actuating rated current of
up to 30 mA (acc. to VDE 0100 part 702 and 738).
The pump is not designed for use in swimming
pools and paddling pools of any kind or other
bodies of water in which people or animals may
be present during operation. 
It is prohibited to operate the pump if a person or
animal is in the danger area.
Ask your electrician!

Before starting to run your new pump, please have
the following items checked by an expert:
- Ground connection
- Zero conductor

Safety circuit breaker switch must correspond
to the safety regulations of the power plants
and they must work faultlessly.

The electrical connections must be protected from
moisture.

If there is danger of flooding, the electrical
connections must be taken to higher ground.

Circulation of aggressive fluids, as well as the
circulation of abrasive materials must be avoided
at all costs.

The pump must be protected from frost.

The pump must be protected from running dry.

Access on the part of children should also be
prevented with appropriate measures.

2. Layout (Fig. 1)

1 Handle
2 Integrated cable rewind
3 Universal hose connection
4 Venting
5 Floating switch
6 Cable holder

3. Installation (Fig. 2)

The pump is installed as follows:

In a stationary position with fixed pipeline
or

In a stationary position with a flexible hose pipe.

You should never install the pump by suspending it
unsupported from its delivery pipe or power cable.
The pump must be suspended from the specially
provided handle or be placed on the bottom of the
shaft. To guarantee that the pump works properly,
the bottom of the shaft must be kept free of sludge
and dirt of all kinds. 

If the water level becomes too low, any sludge in the
shaft will dry out quickly and stop the pump from
starting up. It is necessary, therefore, to check the
submersible motor pump regularly (by carrying out
start-up tests).

The float is adjusted in a way that the pump can
immediately be started

The pump shaft should have minimum dimensions of 
40 x 40 x 50 cm, so that the floating switch can move
freely.

2

Anleitung GLSP 1002_SPK7:Anleitung GLSP 1002_SPK7  27.06.2008  11:25 Uhr  Seite 4

Содержание GLSP1002

Страница 1: ...Operating Instructions N16188 Anleitung GLSP 1002_SPK7 Anleitung GLSP 1002_SPK7 27 06 2008 11 25 Uhr Seite 1...

Страница 2: ...within its intended use over the course of the first year after the date of purchase we will remedy the problem as quickly as possible once it has been brought to our attention In the unlikely event...

Страница 3: ...ction page 5 5 Areas of application page 5 6 Starting up page 5 7 Maintenance instructions page 5 8 Setting the ON OFF switching point page 6 9 Technical data page 6 10 Performance data page 6 10 Wast...

Страница 4: ...ust be protected from moisture If there is danger of flooding the electrical connections must be taken to higher ground Circulation of aggressive fluids as well as the circulation of abrasive material...

Страница 5: ...re cord has been attached properly Check if electrical connection is 240 V 50 Hz Check if socket is in good condition Make sure that water and humidity can never come to the mains supply Avoid pump ru...

Страница 6: ...ase before the pump switches off Caution Risk of running dry 9 Technical Data Power supply 240V 50Hz Power consumption 1 000 Watt Delivery rate max 20 000 L h Delivery height max 8 m Immersion depth m...

Страница 7: ...let sieve is clogged Reduced pumping capacity by dirty and abrasive water Thermal cutout stops pump due to dirty water Water too hot Thermal cutout stops pump Solutions Check mains supply Adjust float...

Страница 8: ...t of documentation and papers accompanying products is permitted only with the express consent of ISC GmbH Technical changes subject to change Never place any electric tools in your household refuse S...

Отзывы: