Gardenline GLGP 1002 Скачать руководство пользователя страница 6

After Sales Support     TEL: 1300 130 579     WEB: www.rossmac.com

6

8. Pressure line connection

The pressure line (should be at least 3/4“) must 
be connected to the pumpʼs pressure line 
connection (1“ IG) either directly or via a threaded 
nipple.

A 1/2“ pressure hose can also be used with the 
appropriate screw connections, of course, but this 
will reduce the delivery rate.

All shut-off devices (spray nozzles, valves etc.) in 
the pressure line  must be fully opened when 
priming so that any air in the intake line can 
escape.

9. Starting up

Set up the pump on flat and firm ground.

Attach the intake line ready for use.

Plug into the mains.

Fill the pump with water at the pressure 
connection.

All shut-off devices in the pressure line (spray 
nozzles, valves etc.) must be fully opened when 
priming so that any air in the intake line can 
escape.

Depending on the suction height and the amount 
of air in the intake line, priming can take anywhere
between 30 seconds and 5 minutes. If it takes 
longer than this, the pump should be refilled with 
water.

If the pump is removed again after use, it must 
always be refilled with water whenever it is 
connected up and used again.

10. Maintenance instructions

The pump is basically maintenance free. To 
ensure a long service life, however, we 
recommend regular checks and care.

Warning!
Before every servicing, switch off the pump 
and remove the plug from the socket.

If the pump is not going to be used for a long time 
or has to be removed for the winter months, rinse 
it out with water, empty it completely and allow it 
to dry.

If there is a risk of frost, the pump must be 
emptied completely.

After long stoppages, make sure the rotor turns 
correctly by briefly switching the pump on and off.

If the pump becomes blocked, connect the 
pressure line to the water line and remove the 

intake hose. Open the water line. Switch on the 
pump several times for approx. 2 seconds. Most 
blockages can be removed in this way.

To drain the pump housing, undo the water drain 
screw (Fig. 3) and tilt the pump slightly.

11. Replacing the mains cable

Warning! Disconnect the pump from the mains!
If the mains cable is defective, it must be
replaced by an electrician.

12. Technical data

Mains supply:

240V ~ 50 Hz

Power rating:

1000 W

Delivery rate max.

4600 l/h

Delivery height max.

45 m

Delivery pressure max.

4.5 bar

Suction height max.

6 m

Delivery and intake connection:

1” IG

Water temperature max.

35°C

Weight

9.3 kg

Anleitung GLGP 1002_SPK7:Anleitung GLSP 1002_SPK7  06.08.2007  8:53 Uhr  Seite 6

Содержание GLGP 1002

Страница 1: ...Operating Instructions Garden Pump GLGP 1002 N16188 After Sales Support TEL 1300 130 579 WEB www rossmac com Anleitung GLGP 1002_SPK7 Anleitung GLSP 1002_SPK7 06 08 2007 8 52 Uhr Seite 1...

Страница 2: ...hin its intended use over the course of the first 2 years after the date of purchase we will remedy the problem as quickly as possible once it has been brought to our attention In the unlikely event o...

Страница 3: ...ing the carry handle page 5 6 Electrical connections page 5 7 Fitting a suction pipe page 5 8 Pressure line connection page 6 9 Starting up page 6 10 Maintenance instructions page 6 11 Replacing the m...

Страница 4: ...Never deactivate the safety devices Use the appliance only for the purposes specified in these instructions for use You are responsible for safety in the work area Should the pump cable or plug be da...

Страница 5: ...on and off using the integrated ON OFF switch The motor is protected against overloading or blocking by an integrated thermostat In the event of overheating the thermostat switches off the pump autom...

Страница 6: ...ed again 10 Maintenance instructions The pump is basically maintenance free To ensure a long service life however we recommend regular checks and care Warning Before every servicing switch off the pum...

Страница 7: ...ivery rate Causes Solutions Suction height too high Check suction height Strainer dirty Clean strainer Water level falling rapidly Immerse intake valve deeper Pump performance diminished by contaminan...

Страница 8: ...of documentation and papers accompanying products is permitted only with the express consent of ISC GmbH Technical changes subject to change Never place any electric tools in your household refuse Se...

Отзывы: