background image

13

GB

12

GB

Cleaning the filter tank

Blocked feed impeller

Connect the power cable to a 230 V AC socket.

A

Caution! Pump will start running immediately! 

Avoid dry operation of the pump as dry running will produce 
undesirable heat and destroy the pump.

.

Loosen the regulator by turning it anti-clockwise until you 

achieve the desired water flow from the vertical pipe of the 
fountain / water feature. The narrow, light grey ring makes it 
easy to screw on another drawing point (e. g. for a stream).

.

You may connect other terminals to the second outlet.

For example, a separately installed water jet may be operated
via the GARDENA Fountain / Light Bracket, Art. No. 7886.
If necessary fix the light jet base with two screws.

Information:
This significantly reduces the volume of the vertical water jet.

.

If the max. delivery capacity of the second outlet is to be used

then the vertical outlet should be closed with the end cap sup-
plied.

.

Example:

Hose pipe connection with the GARDENA light jet base 
We recommend the use of a 3 /4

(19 mm) GARDENA pond

hose pipe, Art. No. 7895, connected to with the GARDENA
“Profi” Maxi-Flow-System with Tap Connector (Art. No. 2801 
and 2802) and the GARDENA "Profi" Maxi-Flow-System Hose
connectors (Art. No. 2817).

Care instructions

Filter tank and pump should be free from dirt particles!

How to clean :

.

Disconnect the plug!

.

Remove the pump from the water.

.

If necessary remove the gravel.

.

Clean the pump and the filter using a water jet.

.

If there are deposits of dirt inside the pump then dismantle the
casing (

see „Dismantling”) and carefully clean the interior 

fittings with water.

Information: Do not use any hard objects or strong detergents!

If the feed impeller becomes blocked, the pump and the filter
should be cleaned (see above).

Starting the pump 

Avoid dry operation 

Horizontal or 
second outlet 

Remote control 

Pond aeration 

Filling the filter tank 
with zeolith 

Information

Example for application:

For operating water jets from the comfort of your patio or
your living room.

Products:

GARDENA Remote Control Set

Art. No. 7874 

GARDENA Remote Control Socket

Art. No. 7875 

Example for application:

To aerate the pond.

Product :

GARDENA Pond Aerator

Art. No. 7936

Zeolith fulfils the following functions:

.

Filters the water (

protection for the pump).

.

Bonds with excessive nutrients and causes their decomposition

by bacteria (

Ion exchange and the bonding of e.g. nitrate).

.

Helps to keep the pond clean and maintain the biological 

balance.

.

Provides stability for the pump.

GARDENA Zeolith, 1 l

Art. No. 7914 

GARDENA Zeolith, 5 l

Art. No. 7915 

Note :
To ensure the zeolith functions correctly, we recommend you 
replace or clean it every 6 months (e.g. in salt water).

.

Always unplug the pump first before working on it.

.

Before assembling system extensions first unscrew the pre-
assembled cascade and if necessary also the telescopic tube
of the pump and then screw one of the water jets on again 
(

the ball-and-socket joint ensures that the water jet is 

vertical).

.

Follow the Safety and Assembly Information attached to the
operating instructions.

Operation

1. Remove the pump from the filter basket and screw the regulator 

supplied onto the second opening of the pump up to the limit
stop (

max. delivery capacity on the vertical outlet). Then

replace the pump in the filter basket.

2. Put the pump on a stable base to ensure that the upper edge 

of the filter tank is completely immersed in water.

Please note the maximum submersion depth (see “Technical Data”).

Installing the pump 

Pay attention to 
minimum water depth 

Содержание WP 600

Страница 1: ...loi Pompe pour jets d eau NL Gebruiksaanwijzing Waterspelpomp S Bruksanvisning Font n Pump Set I Istruzioni per l uso Pompa per giochi d acqua E Manual de instrucciones Bomba para juegos de agua DK Br...

Страница 2: ...kname van het apparaat zorgvuldig door Pagina Gebruiksaanwijzing 22 27 S L s igenom bruksanvisnin gen noggrant innan Du tar Din GARDENA Pump i bruk Sida Bruksanvisning 28 33 I Prima di mettere in uso...

Страница 3: ...rating of 30 mA DIN VDE 0100 702 and 0100 738 The pump must be placed on solid even ground Please ask your electrician for his advice Mains power cables Mains power cables should not have a smaller c...

Страница 4: ...s If the feed impeller becomes blocked the pump and the filter should be cleaned see above Starting the pump Avoid dry operation Horizontal or second outlet Remote control Pond aeration Filling the fi...

Страница 5: ...the receipt and a description of the fault with postage paid to one of the GARDENA Service Centres listed on the back of these operating instructions Where to store Dismantling 1 Disconnect the plug 2...

Страница 6: ...ne Springvandspumper Typ WP 600 Art Nr 7849 Type Art No Type WP 900 R f rence 7852 Typ Art nr Typ WP 1200 Art nr 7855 Modello Art Tipo WP 1800 Art N 7858 Type Varenr WP 2500 7859 EU Richtlinien 98 37...

Страница 7: ...ENA Magyarorsz g Kft K sm rk utca 22 1158 Budapest Iceland Heimilistaeki hf Saetun 8 P O Box 5340 125 Reykjavik Republic of Ireland Michael McLoughlin Sons Hardware Limited Long Mile Road Dublin 12 It...

Отзывы: