Voltage

Cable length

Cross section

230 – 240 V / 50 Hz

Up to 20 m

1.5 mm

2

230 – 240 V / 50 Hz

20 – 50 m

2.5 mm

2

  

DANGER! Electric shock!

With a cut off mains plug, moisture can get into electrical parts via the 

mains cable and cause a short circuit.

v

  Never cut the mains plug off (e. g. to feed through wall).

v

  Don’t use the power cable for plugging off.

v

  If the supply cord is damaged, it must be replaced by the manufacturer,  

its service agent or similarly qualified persons in order to avoid a hazard.

Mains plug and extension connections must be protected from water splashes.
Ensure that the electrical connections for plugs and sockets are made in areas 

safe from flooding.
Protect the mains plug and the mains power cable from heat, oil and sharp 

edges.
Observe the mains voltage. The information on the nameplate must be in 

 agreement with the data for the mains power grid.
The pump’s mains plug must be disconnected before anybody enters the 

 swimming  pool.
The mains power cable must not be used for fastening or transporting the  

pump. 
For submerging or lifting / securing the pump, please use the fastening rope.
Please regularly check the connecting line.
Before using, always subject the pump (especially the power cables and the 

power connections) to a visual inspection.
A pump which is damaged should not be used. In the event of damage, have  

the pump checked by GARDENA Service.
Do not disassemble the pump any further than the delivery condition.
Before use after maintenance, make sure that all parts are screwed together.
When using our pumps with a generator, the warnings of the generator 

 manu facturer must be observed.

Personal safety

  

DANGER! Risk of suffocation!

Small parts can be easily swallowed. There is also a risk that the poly-

bag can suffocate toddlers. Keep toddlers away when you assemble the 

product.
Observe the minimum water level in accordance with the characteristics given  

for the pump.
Only for Art. 1768: Allow the pump to run no longer than 10 minutes against 

a closed pressure side.
Sand and other abrasive substances cause increased wear and reduce the 

pump’s output.
The pump must not be used to increase the pressure through the thread on  

the inlet side.
Only the GARDENA floating suction system may be mounted on the thread on 

the inlet side.
The float switch may only be operated outside the water.
The hose must not be disconnected during operation.
Allow the pump to cool down before troubleshooting.

IMPORTANT! 

Read the operator’s manual carefully before use and keep for future 

 reference.

Symbols on the product:

 

Read operator’s manual.

General safety warnings
Electrical safety

 DANGER! Electric shock!

 

Risk of injury due to electric current.

v  

The product must be supplied through a residual current device (RCD) 

having a rated residual operating current not exceeding 30 mA.

 DANGER! Risk of physical injury!

 

Risk of injury due to electric current.

v

  Disconnect the product from the mains before you maintain or replace 

parts. Thereby the disconnected socket must be in the visual range.

Safe operating practices
The water temperature should not exceed 35 °C.
The pump must not be used when people are in the water.
Pollution of the liquid could occur due to leakage of lubricants.

Circuit breakers
Dry-running protection:
 

If the water level is too low, the pump switches off automatically.

v  

Submerge the pump deeper into the water.

Thermal protection switch: 

In the event of an overload, the pump is switched off by the built-in thermal motor 

protection. After sufficient cooling of the motor, the pump is operational again.
Leakage protection (only for  Art.  1771 / 1773):   

The event of leakage on the pressure side (e. g. leaking pressure hose or tap) 

switches the pump on and off at short intervals. If the pump is switched on and 

off more frequently than 7 x in 2 min. (with a leakage < 6 l/hr), the pump switches 

off completely. When the leakage on the pressure side is eliminated, the pump 

must be unplugged and plugged in again in order to be operational again.

Automatic venting
This pump is equipped with a vent valve which eliminates any air pockets in the 

pump. Depending on the function, a small amount of water can escape below 

the handle.

Additional safety warnings
Electrical safety

  

DANGER! Cardiac arrest!

This product makes an electromagnetic field while it operates. This  

field may under some conditions interfere with active or passive medical 

implants. To decrease the risk of conditions that can possibly injure or 

kill, we recommend persons with medical implants to speak with their 

physician and the medical implant manufacturer before you operate the 

product.

Cables
If extension cables are used, these must comply with the minimum cross- 

sections in the table below:

1. SAFETY

Intended use:
The GARDENA Submersible Pressure Pump is intended for the extrac-

tion of water from wells, shafts and other water reservoirs, for the opera-

tion of irrigation equipment and systems, also for pumping rainwater, tap 

water and water containing chlorine. Art. 1771 / 1773 are also intended  

for domestic water supply in private domestic gardens and allotments.

Liquids to be pumped:
The GARDENA Submersible Pressure Pump must only be used to pump 

water. The pump is fully submersible (water-tight encapsulation) and is sub-

merged in water (for max. submersion depth, see 7. TECHNICAL DATA). 

The pump is equipped with an integrated check valve, which prevents 

automatic drainage of the pressure hose when the pump is shut down.
The product is not intended for long term use (continuous circulation 

 operation).

 

 

DANGER! Risk of injury!  

The pump should not be used for the delivery of salt water,  

muddy water, corrosive, easily inflammable or explosive liquids 

(e. g. petrol, paraffin, thinners), oil, heating oil or foodstuffs.

2. ASSEMBLY

  

 DANGER! Risk of injury!

 

Injury when the product starts accidentally.

v  

Disconnect the product from the mains before you assemble 

the product.

The hose can be connected via the pump connection 

(1)

 and the connec-

tion nipple 

(2)

 [19 mm (3/4") / 25 mm (1")] or via the GARDENA Connection 

System [13 mm (1/2") / 16 mm (5/8") / 19 mm (3/4")]. When using a 25 mm 

(1") hose, the pump has the maximum delivery capacity.
With a parallel connection of more than one hose or connected devices, 

the GARDENA 2- / 4-Way Valve (Art.  1210 / 1194) can be used. 

Connect hose via connection nipple [ Fig. A1 ]:
25 mm (1")- and 19 mm (3/4") hoses can be connected via the connection 

nipple 

(2)

.

Hose diameter

25 mm (1")

19 mm (3/4")

GARDENA Hose Clamp

Art. 7192

Art. 7191

Hose connection  

[ Fig.  A1 ]

Detach nipple  

at 

<

 [ Fig.  A2 ].

Do not detach 

 nipple  [ Fig.  A3 ].

EN

8

EN

Содержание inox automatic 5900/4

Страница 1: ...aszn lati utas t s Mer l nyom szivatty CS N vod k obsluze Ponorn tlakov erpadlo SK N vod na obsluhu Ponorn tlakov erpadlo EL RU SL Navodilo za uporabo Potopna tla na rpalka HR Upute za uporabu Potopna...

Страница 2: ...dnie z niemieck ustaw o odpowiedzialno ci za produkt niniejszym wyra nie o wiadczamy e nie ponosimy adnej odpowiedzialno ci za szkody poniesione na skutek u ytkowania naszych produkt w w przypadku gdy...

Страница 3: ...3 A1 2 A2 Art 7192 2 1 A3 Art 7191 2 1 A4 A5 1 A6 8 A7 0 9 O2 min 100 mm min 30 cm 6 O1 3 5 4 O3 6 O4 6 M1 7...

Страница 4: ...and the resulting dangers have been under stood by children aged 8 and above as well as by persons with physical sensory or mental disabilities or a lack of expe rience and knowledge Children must no...

Страница 5: ...of the liquid could occur due to leakage of lubricants Circuit breakers Dry running protection If the water level is too low the pump switches off automatically v Submerge the pump deeper into the wat...

Страница 6: ...in the hose until water is drawn via the hose To adjust the Cut in and Cut out Height Fig O3 The maximum cut in height and minimum cut out height see 7 TECHNICAL DATA can be adjusted by pushing the fl...

Страница 7: ...m Possible Cause Remedy Pump is running but the delivery drops Filter is clogged v Clean the filter see 4 MAINTENANCE NOTE For any other malfunctions please contact the GARDENA service depart ment Rep...

Страница 8: ...as a manufacturer such as for damages This manu facturer s warranty does not of course affect statutory and contractual warranty claims against the dealer retailer The manufacturer s warranty is gover...

Страница 9: ...stiky erpadla Karakteristika rpalka Obilje ja pumpe Karakteristika pumpe Caracteristic pomp Pompa karakter e risi Fuqia e pomp s Pumba karakteristik Siurblio charakteristin kreiv S k a raksturl kne ma...

Страница 10: ...talt med os mister denne erkl ring sin gyldighed FI EU vaatimustenmukaisuusvakuutus Allekirjoittanut vahvistaa valmistajan GARDENA Germany AB PO Box 7454 S 103 92 Tukholma Ruotsi valtuuttamana hen kil...

Страница 11: ...rdena husqvarna co uk Italy Husqvarna Italia S p A Via Santa Vecchia 15 23868 VALMADRERA LC Phone 39 0341 203 111 assistenza italia it husqvarna com Japan KAKUICHI Co Ltd Sumitomo Realty Development K...

Отзывы: