3. Function 

1

Time

key :                   Selects date and time.

2

Channel

key :             Calls the channels.

3

Man.

key :                   Manually opens / closes individual 

                                 channels.

4

% Run-Time

key :       Calls up the % run-time function.

5

Rain Off

key :             Selects a watering break. 

6

-

keys :                  Changes data already entered. 

                                 (If you press and hold down the 

-

                                 keys you can change data in the quick 
                                 run-through mode.) 

7

OK 

key :                      Confirms the settings you selected 

                                 using the

-

keys.

8

Date and time display : 

Indicates the day of the week, date and current time. 

9

Status display : 

Indicates the current programming or watering status. 

0

% Run-Time display : 

Sets the duration of watering between 10 - 200 % for all 
channels. 

A

Key lock : 

Protects against unintentional changing of settings (the reset
function cannot be locked). 

B

Battery status display : 

When the 

Low Battery 

display flashes, the battery is almost

empty and has to be replaced. 

When the 

Low Battery

display appears, the battery is empty 

or no battery has been inserted. 

The 

Low Battery

display is re-set once the new battery has

been inserted.

The Watering Controller must be used only for controlling
commercially available 24 V (AC) valves. The electric power
consumption per channel must not exceed 600 mA
(a GARDENA Irrigation Valve Art. 1278 requires 150 mA). 

Please note

2. Safety Instructions 

Watering Controller : 

The Watering Controller must only
be operated with the 24-V (AC)
power supply unit provided.

v

Protect the 24-V (AC) power supply unit
from moisture when connected.

The Watering Controller is not splash proof. 

In order not to lose any data in the event of
power failure, an alkaline 9 V block battery
(type 6LR61) must be used for buffering data.
We recommend using batteries manufactured
by Duracell and Energizer (do not use
rechargeable batteries).

Keypad : 

Watering Controller display : 

7

1

2

3

4

5

6

8
9
B

F

E

0
A

G

C

D

Содержание 4030

Страница 1: ...F Mode d emploi Programmateur NL Gebruiksaanwijzing Besproeiingscomputer S Bruksanvisning Kontrollpanel DK Brugsanvisning Vandingskontrol system FIN Brugsanvisning Kastelunohjauslaite N Brugsanvisning...

Страница 2: ...Please keep these instructions in a safe place 1 Where to Use your GARDENA Watering Controller 15 2 Safety Instructions 16 3 Function 16 4 Initial Operation 17 5 Operation 19 6 Putting Out of Operatio...

Страница 3: ...the battery is almost empty and has to be replaced When the Low Battery display appears the battery is empty or no battery has been inserted The Low Battery display is re set once the new battery has...

Страница 4: ...24 V AC terminals only Before programming your Watering Controller install a 9 V battery to prevent loss of data if a power failure occurs 1 Release snap lock 1 and open cover 2 2 Connect the cable of...

Страница 5: ...le terminals C are interconnected and equivalent to one another 4 Connect one cable of the valve V2 to the cable terminal 2 of the valve box 5 Connect the other cable of the valve V2 to a cable termin...

Страница 6: ...e week is selected automatically using the date When the Time key is pressed all the valves are clo sed as a precaution 1 Plug in the power supply unit or press the Time key YEAR and date year flash i...

Страница 7: ...annel key SELECT CHANNEL and the channel flash You can end the programming mode at any time by pressing the Channel key 2 Select the channel using the keys e g channel 2 and confirm by pressing the OK...

Страница 8: ...OK key The selected watering days e g Mo We Fr are shown on the display in frames 9 Press the Channel key and set up more watering programs The program is saved and SELECT CHANNEL and the channel fla...

Страница 9: ...nel e g channel 2 is shown in the display If several channels are blocked Channels off is displayed If the run time is not equal to 100 the display alternates every 3 seconds between Channel off and R...

Страница 10: ...confirmed within 10 seconds by pressing the OK key the watering begins with the watering duration displayed You can exit watering all the channels prematurely by pressing the OK key Man key for 3 seco...

Страница 11: ...ak 1 to 9 or they can all be blocked Off in which case manual watering is still possible 1 Press the Rain Off key Rain Off and Off is displayed 2 Using the keys set the desired break e g 3 days 3 Day...

Страница 12: ...FF The power supply unit is not v Plug the power supply unit is indicated on the display plugged in into a mains socket the programs are retained Overload The power supply is over v Only so many valve...

Страница 13: ...n of the problem directly to one of the GARDENA Service Centres listed on the back of this leaflet A In the event of other faults please contact GARDENA Service Repairs should only be carried out by G...

Страница 14: ...e Th Fr Sa Su 1 2 3 Channel Prog START TIME RUN TIME 24 h 2nd 3rd Odd Even Mo Tu We Th Fr Sa Su 1 2 3 Channel Prog START TIME RUN TIME 24 h 2nd 3rd Odd Even Mo Tu We Th Fr Sa Su 1 2 3 Channel Prog STA...

Страница 15: ...oduktansvar Vi g r udtrykkeligt opm rksom p at i henhold til produktansvarsloven er vi ikke ansvarlige for skader for rsaget af vores udstyr hvis det skyldes uautoriserede reparationer eller hvis dele...

Страница 16: ...onformit alle norme UE La sottoscritta Husqvarna AB 561 82 Huskvarna Sweden certifica che il prodotto qui di seguito indicato nei modelli da noi commercializzati conforme alle direttive armonizzate UE...

Страница 17: ...td Preston Road Aycliffe Industrial Park Newton Aycliffe County Durham DL5 6UP info gardena husqvarna co uk Italy Husqvarna Italia S p A Via Como 72 23868 VALMADRERA LC Phone 39 0341 203 111 info gard...

Отзывы: