background image

EN

8

v

  Before operating the pressure tank unit, first make a visual check to ensure 

there is no damage to the pressure tank unit (especially regarding power cable 

and plug).

A damaged pressure tank unit must not be used.

v

  In case of damage, please have the pressure tank unit checked by our 

 GARDENA Service Centre or by an  authorised electrician.

Protect the pump from rain. Do not use the pressure tank unit in a wet or moist  

area.
In order to avoid dry-running of the pressure tank unit, take care that the end of 

the suction hose is always submerged into the liquid.
The pressure tank unit must not be run dry nor with the stopcock in the suction 

pipework closed.

v

  Before each operation, fill the pressure tank unit to overflowing with approx. 

2 to 3 l of the liquid to be pumped!

Sand and other abrasive substances in the liquid cause increased wear and 

reduce the pump’s output.
When using the pump for domestic water  supply, please adhere to the local 

water and sewerage regulations. In addition observe the regulations of DIN 1988.

v

  If necessary contact your local water  authority.

DANGER! This product makes an electromagnetic field while it operates. This 

field may under some conditions interfere with active or passive medical implants. 

To decrease the risk of conditions that can possibly injure or kill, we recommend 

persons with medical implants to speak with their physician and the medical 

implant manufacturer before you operate the product.
DANGER! Small parts can be easily swallowed. There is also a risk that the poly-

bag can suffocate toddlers. Keep toddlers away when you assemble the product.

2. INITIAL OPERATION

Installing the Pressure Tank Unit:
The installation position must be firm and dry, and permit a secure 

 mounting for the pressure tank unit.

v

  Install the Pressure Tank Unit at a safe distance from the  pumping 

medium.

The pump must be installed in a location with low air humidity and suffi-

cient ventilation in the area of the ventilation slots. It must be at a distance 

of at least 5 cm from the walls. No dirt contamination (e. g. sand or earth) 

may be sucked in through the ventilation slots.

Fixed installation of the Pressure Tank Unit [ Fig. I1 ]:

v

  The Pressure Tank Unit can be screwed with all 4 feet 

2

 onto a solid 

surface 

1

.

Alternatively, spring mounted feet (Art. 1753-00.901.00) for low vibration 

and quiet  running are available as accessories via the GARDENA Service.
Install the pressure tank unit so that there is room to place a  suitably sized 

drainage tray under the drain screw 

3

 to allow the unit or system to be 

drained. 
If possible, install the unit higher than the surface of the water to be 

pumped. If this is not possible, install a vacuum-resistant valve between 

the unit and the suction hose, for example for cleaning the integrated filter. 

If the pump is permanently installed indoors for domestic water supply, 

the Pressure Tank Unit should not be connected to the domestic water 

pipework with rigid pipes but with flexible tubing, to reduce noise and to 

avoid damage to the pump caused by pressure blows.

If the system is being installed permanently, please fit suitable  valves on 

both the intake and delivery sides. This is important e. g. for maintenance 

and cleaning work or if the system is being shut down.

The connection pieces on the intake and delivery sides may only 

be tightened by hand.

Connect the hose to the suction side [ Fig. I2 ]:

A vacuum-tight suction hose must be used e. g.:
– GARDENA Suction Unit Art.  no.  1411 / 1418 / 1412 or
– GARDENA Bore Hole Suction Hose Art. no. 1729.

Do not use any water hose snap connection system components on the 

intake side!

v  

Connect the suction hose 

5

 with the intake side  

connection 

6

 of the pump.

Connect the suction hoses 

5

 without a threaded connector via a connec-

tion piece (e.g. Art. no. 1723/1724

4

 with the intake side connection 

and screw in place so that they are airtight.
To reduce the pump repriming time, we recommend using a suction hose 

with backflow preventer, which prevents the  suction hose emptying auto-

matically when the Pressure Tank Unit is switched off. 
For suction heights exceeding 4 m also secure the suction hose 

5

  

(e. g. by fastening it to a wooden post) to relieve the pump of the weight  

of the suction hose.

If very fine dirt is present in the pumping medium, we  recommend the 

use of a GARDENA Pump Preliminary Filter Art. no. 1730 / 1731

Connect hose to the output side [ Fig. I3 ]:

Note:

Use pressure-tight GARDENA hoses, 19 mm (3/4") in diameter, in 

connection with the GARDENA Quick-Release Threaded  Connector with 

33.3 mm (G1) internal thread, Art. no. 7109, and the GARDENA Suction 

and High Pressure Connector, Art. no. 7120, for 19 mm (3/4") hoses 

and a GARDENA Hose Clip, Art. no. 7192.

Under no circumstances use these hoses on the suction side.

1.

  

Connect the delivery hose 

7

 with one of the three  connections 

8

 

to the delivery side. 

2.  Unused pressure connections must be closed off with an end 

cap 

9

.

Tip: With fixed piping, only assign max. 2 connections 

8

 so that the air 

can be bled off via the end cap 

9

 of the third  connection. Permanent 

pipes must be laid at an ascending angle in order to allow the water to 

flow back into the pump on the pressure side.

3. OPERATION

Starting  the  Pressure  Tank  Unit  [ Fig.  O1 / O2 / O3 ]:

  

 DANGER! Electric shock!

 v 

 Before filling the pump, unplug the equipment from the 

mains.

CAUTION!

v

  Fill the pump to the overflow (approx. 2 to 3 l) with water each 

time before the pump is switched on.

1.  Turn the rotary switch 

q

 to OFF.

2.  Unscrew the cover 

0

 of the filter chamber by hand.

3.  Open an end cap 

9

 on the delivery side to bleed off the air.

4.  Open any valves in the delivery line (watering accessories, water stop, 

etc.) and drain off any residual water in the delivery hose so that the air 

can escape during filling and priming.

5.  Slowly pour pumping medium (approx. 2 to 3 l) through the filler neck 

e

 until water emerges from the open delivery side connection 

8

.

6.  Screw the filter chamber cover 

0

 closed again, turning by hand until it 

stops.

7.  Close the end cap 

9

 on the delivery side which had been ope­

ned to bleed off the air.

8.  Insert the mains plug into a 230 V mains socket. 
9.  Turn the rotary switch 

q

 to START.The pump will start immedi­

ately!

Once priming has taken place, the rotary switch switches auto matically to 

AUTO and the dry-running safety is activated. Once the maximum pressu-

re is reached the pump will switch off auto matically. When the pressure falls 

below the minimum value due to water being drawn off, the pump will 

switch on again automatically.

  

CAUTION!

 

   If the pump has not started priming after 10 min.,  

turn the rotary switch 

q

 to OFF.

 

v

  See 6. TROUBLESHOOTING “The pump sucks nothing up”.

The maximum self-priming head of 8 m is only achieved if the pump is fil-

led until it overflows from the filler connection 

e

 and the delivery hose is 

held high enough during self-priming so that no water can escape from 

the pump via the delivery hose. It is not necessary to hold up the delivery 

hose if filled suction hoses with backflow preventer are used.

Manual mode (Man.) [ Fig. O4 ]:
When conveying very large water quantities at very low pressure, the 

pump switches off in Auto mode for safety reasons. However, should this 

operation be required, the pump can be operated in manual mode 

(Man.)
Warning: This deactivates the dry­running safety.

v  

Pull the rotary switch 

q

 and turn to Man. 

The pump will start.

Содержание 4000/5 eco

Страница 1: ...ό με βαρέλι RU Инструкция по эксплуатации Станция бытового водоснабжения автоматическая SL Navodilo za uporabo Hišna vodna črpalka HR Upute za uporabu Kućni hidroforska pumpa SR Uputstvo za rad BS Kućna hidroforska pumpa UK Інструкція з експлуатації Домова водопровідна станція RO Instrucţiuni de utilizare Hidrofor cu rezervor TR Kullanma Kılavuzu Konut Suyu Tertibatı BG Инструкция за експлоатация ...

Страница 2: ... 4 5 6 I3 9 8 7 O1 q O f f Man Auto S t a r t O4 q O f f Man Auto S t a r t O2 0 9 e 8 O3 q O f f Man Auto S t a r t O5 ECO MAX r S1 t 9 M1 z 0 u M2 A B z u M3 E H 9 T1 s a TD1 447 mm 615 mm 549 mm 294 mm 153 mm 292 mm 146 mm 576 mm ...

Страница 3: ...rmer v Please ask your electrician for his advice In Switzerland In Switzerland portable devices that are used outdoors must be connected through an earth leakage circuit breaker Mobile appliances that are used out doors must be connected via a residual current device General safety warnings Risk of injury due to hot water If the pressure switch is defective or if the water supply on the intake si...

Страница 4: ...ection system components on the intake side v Connect the suction hose 5 with the intake side connection 6 of the pump Connect the suction hoses 5 without a threaded connector via a connec tion piece e g Art no 1723 1724 4 with the intake side connection and screw in place so that they are airtight To reduce the pump repriming time we recommend using a suction hose with backflow preventer which pr...

Страница 5: ...ter is able to flow back into the pressure line see 3 OPERATION Air cannot escape on the pres sure side because the pressure side outlets are closed v Open the pressure side outlets End of the suction hose is not in the water the non return valve at the end of the suction hose is missing or leaking the suction hose is kinked connec tions are leaking or the suction filter is blocked v Check the com...

Страница 6: ...LWA 1 measured guaranteed Uncertainty kWA 1 dB A 83 84 2 1 87 88 2 1 87 89 2 3 Measuring process complying with 1 RL 2000 14 EG NOTE The stated vibration emission value has been measured according to a standardized test procedure and can be used for comparison of one electric power tool with another It can also be used for preliminary evaluation of exposure The vibration emission value can vary du...