14
GB
Flushing the Pump :
Cleaning the suction
base and impeller :
9
A
0
9
Flat suction :
Normal operation :
v
Turn the 3 swivel feet
8
v
Turn the 3 swivel feet
8
180° to
1 mm
.
180° to
5 mm
.
The residual water level of approx. 3 mm is only reached during
flat suction in the manual operation mode.
5. Putting into Storage
v
Store the pump away from frost before the first frost sets in.
The product must not be added to normal household waste. It
must be disposed of in line with local environmental regulations.
v
Important: Make sure that the unit is disposed of via your
municipal recycling collection centre.
6. Maintenance
The pumps are virtually maintenance-free.
After having pumped chlorinated swimming pool water or other
liquids leaving residues, the pump should be rinsed with clear
water.
DANGER ! Electric shock !
A
Risk of injury due to electric shock.
V
Disconnect the pump from the mains before
cleaning the suction base and impeller.
1. Unscrew the 6 Phillips screws
9
and pull the suction base
0
off the pump.
2. Clean suction base
0
and impeller
A
.
3. Reinstall the suction base
0
and screw in the Phillips screws
9
.
For safety reasons a damaged impeller
A
can only be ex-
changed by the GARDENA Service Centre.
Frost-free storage :
Disposal :
(in accordance with
RL 2002 / 96 / EC)
Only for 21000 inox :
Flat suction /
Normal operation
8