5. Putting into Storage
Overwintering / Storage:
9
Before the start of the frost period the Garden Pump should be
stored protected from frost.
1. Open the water drain screw
9
.
The Garden Pump drains.
2. Store your Garden Pump so that it is protected from frost.
Disposal:
(in accordance with
RL 2012/19/EU)
The product must not be added to normal household waste.
It must be disposed of in line with local environmental regulations.
6. Maintenance
DANGER! Electric shock!
Risk of injury due to electric shock.
v
Disconnect Garden Pump from the mains before
carrying out maintenance.
Cleaning the filter:
If the filter is dirty it has to be cleaned.
A
6
1. Close all shut-off valves,
if any, on the suction side.
2. Unscrew and remove cover
6
of the filter chamber.
3. Draw out filter unit vertically
upwards.
4. Hold beaker
0
firmly, turn
filter
q
anti-clockwise
1 and
draw out
2 (bayonet fitting).
5. Clean beaker
0
under
running water and clean the
filter
q
e. g. with a soft brush.
6. Refit filter again in reverse order.
1
2
A
0
Flush through Garden Pump:
The pump must be flushed through after discharging chlorinated
swimming pool water.
1. Pump through lukewarm water (max. 35 °C), possibly adding
a mild cleaning agent (e.g. detergent) until the pumped water
runs clear.
2. Remove residuals according to the waste disposal laws
applicable in your area.
18