Garden Leisure Garden-696L Скачать руководство пользователя страница 15

12

CONTROL PANEL OPERATION

ECONOMY MODE: 

The spa will not heat. Water 

sampling only done during the filter cycle.

SLEEP MODE:

 

The spa will only heat during the 

filter cycles. Water sampling only done during the filter 

cycle.

QUIET MODE:

 

Keeps the jet pump from 

running (water sampling) after the F2 filter cycle 

is complete for up to 11.5 hours. You can set this 

mode between 0.5 hours and 11.5 hours in half 

hour increments. To enter the programming screen 

and toggle between Standard, Economy, Sleep and 

Quiet Modes the following is required:

FAHRENHEIT/CELSIUS 

SETTING: 

To change water temperature display to either 

Fahrenheit or Celsius, press and hold 

Light

 

button for 5+ seconds until F1 is displayed. 

Press the 

Light

 button several times until F or C 

is displayed. Press the 

Plus

 or 

Minus

 button to 

change. Wait 15 seconds to allow the exit timer to 

expire and store the setting.

OPERATIONAL MODES

 

(Garden-

696L, Garden-680L & Garden-780L 

models only)

SETTING THE CLOCK 

1.  Enter the program menu by holding down the 

Light

 button for 5 seconds. The display will 

show the current clock setting with the hour 

flashing.

2.  Your system is set to a 24-hour time. 
3.  Setting the hour: Use the 

Up/Down

 button 

to adjust the hour. Press the 

Light

 button to 

jump to the next parameter, the minutes.

4.  Setting the minutes: Use the 

Up/Down

 button 

to adjust the minutes. Press the 

Light

 button 

to jump to the next parameter, the filter 

cycles.

NOTE:

 If your spa loses power the clock will need 

to be reset once power is regained. 

FILTER CYCLES 

Program the start time, duration and frequency of 

your filter cycles. The default duration for the filter 

cycles is 1 hour (2 times per day spread out by  

12 hours) if the clock is not set and will start at 

12. Filter cycles only run at low speed, however, 

the second pump will purge for a minute first 

during each filter cycle . The “Filter” indicator   

lights up when a filter cycle is on. The duration of 

each filter cycle can also be modified. 

SETTING THE FILTER CYCLES

To program the filter cycle start time, duration 

and frequency the following is required: 

1.  Press and hold 

Light

 button for 5 seconds 

until clock hour is displayed (this time 

should already be programmed, press 

Light

 button two more times until FSxx is 

displayed where xx represents the hour to 

set the filter cycle. 

2.  Press the 

Up /Down 

button to adjust the 

clock time for the first filter cycle to start (on 

the hour only). 

3.  Press the 

Light

 button to store the cycle 

start time and move to Fdxx the duration of 

the filter cycle(s) where xx represents the 

length of filter cycle time in hours

4.  Press the 

Up /Down 

button to adjust the 

duration (how long to run the filter cycle) 

from 0 = no filtration to 24 = continuous 

filtration. 0 is NOT recommended.

NOTE:

 The set duration will be the same time 

length for each frequency.

5.  Press the 

Light

 button to store the duration 

and move to FFxx the frequency of the filter 

cycle(s) where xx represents the amount of 

times the filter cycle should come on.

6.  Press the 

Up +/Down - 

button to adjust the 

frequency (how many filter cycles within a 

24 hour period). The amount of frequencies 

allowed will depend on how long the duration 

is set to since there are only 24 hours in a 

day (example: if the duration is set to  

13 hours or more than only 1 frequency can 

be set, 9 - 12 hour duration only  

2 frequencies can be set.  In other words 

the duration times the frequency must be 24 

or less.

7.  Wait 15 seconds to allow the exit timer to 

expire and store the setting.

Содержание Garden-696L

Страница 1: ...OWNER S MANUAL 50HZ...

Страница 2: ...0 lbs 1 211 L 320 gal Garden 780 7 person 213 cm 84 213 cm 84 91 cm 36 376 kg 830 lbs 1 317 L 348 gal Garden 642L 6 person 213 cm 84 213 cm 84 91 cm 36 367 kg 810 lbs 1 208 L 319 gal Garden 742 7 pers...

Страница 3: ...S 11 OPERATIONAL MODES GARDEN 642L GARDEN 742 GARDEN 334L MODELS ONLY 12 DIAGNOSTIC LCD MESSAGE 13 COMPONENT OPERATION SPACOMPONENT OPERATION 14 FILL UP AND START UP INSTRUCTIONS FILLING THE SPAWITH W...

Страница 4: ...only to a grounded source Do not bury the power cord A buried power cord may result in death or serious personal injury due to electrocution if direct burial type cable is not used or if improper digg...

Страница 5: ...ectrocution if the appliance should fall into the spa Install your spa in such a way that drainage is away from the electrical compartment and from all electrical components DO Be sure your spa is con...

Страница 6: ...on for at least ten minutes after adding ANY spa water chemicals into the filter compartment Clean the filter cartridge monthly to remove debris and mineral buildup which may affect the performance of...

Страница 7: ...ls and cleaners DON T Leave the spa exposed to the sun without water or the cover in place Exposure to direct sunlight can cause solar distress of the shell material Roll or slide the spa on its side...

Страница 8: ...nstallations require adequate ventilation When the spa is in use considerable amounts of moisture are produced This moisture can damage walls and ceiling surfaces over time Special paint is available...

Страница 9: ...o the spa area An architect can help to determine if more ventilation must be installed PLACING THE SPA CHECK THE DIMENSIONS OF YOUR SPA Compare the spa dimensions to the width of gates sidewalks and...

Страница 10: ...panel slightly pull bottom of door away from spa then remove Equipment Compartment EQUIPMENT ACCESS PANEL Electrical Access Electrical Access Serial No LEFT SIDE OF SPA FOR HEAT PUMP ONLY Front side...

Страница 11: ...e labeled and easily accessible to users 4 The electrical supply for the spa must include a suitable circuit breaker to open all ungrounded supply conductors to comply with your National local code Th...

Страница 12: ...e electrical service using one 40 amp breaker with 3 wires The spa must be connected to a dedicated RCD circuit breaker that is not shared with any other equipment Do not use extension or plug type co...

Страница 13: ...rrent spa temperature The heater indicator lights up when the heater is on It flashes when there is a request for more heat but the heater is not on Once set temperature is reached the indicator shuts...

Страница 14: ...for 5 seconds until F1 is displayed 2 Press the Plus or Minus button to adjust the cycle time for F1 3 Press the Light button to store the F1 cycle and move to the F2 cycle 4 Press the Plus or Minus...

Страница 15: ...ur 2 times per day spread out by 12 hours if the clock is not set and will start at 12 Filter cycles only run at low speed however the second pump will purge for a minute first during each filter cycl...

Страница 16: ...nnection instructions Installation must be performed by a licensed electrician and all grounding connections must be properly installed SETTING ECONOMY MODE In Economy mode you are able to lower the s...

Страница 17: ...FAC Aquaterra recommends that a chemical maintenance program based on recognized and documented industry standards still be followed when using an ozone purification system to assure water sanitation...

Страница 18: ...tem and invalidate your warranty If your spa filter is sucking in air causing the pump to cavitate you need to add water 7 Check the filter installation and make sure the filter is not loose APPLYING...

Страница 19: ...ty Up Increaser sodium bicarbonate or sodium hydrogen carbonate These products should be added in small amounts 1 tablespoon at a time After adding wait one half hour before re measuring Once the safe...

Страница 20: ...button for 8 second to OFF 2 Pull out the basket and weir Carefully unscrew the filter cartridge and bring it out of the spa 3 Always clean the filter using a filter degreaser to remove mineral and oi...

Страница 21: ...er and air dry IMPORTANT Do not let the polyester dry with a soap film on it before it can be rinsed clean 4 Scrub the cover s perimeter and side flaps Rinse clean with cold water 5 Rinse off the unde...

Страница 22: ...nes and jets a It will be necessary to remove all water from the interior plumbing b Remove the floating weir basket and filter cartridge Clean the filter cartridge and store in a dry place Attach the...

Страница 23: ...ed jet action 3 Make sure the water level is half way between top of spa and top of the gray filter ring 4 Check for dirty filter Clean if necessary 5 Make sure all jets are in the open position WATER...

Страница 24: ...21 305314 24 A 9 23...

Отзывы: