INSTALLATION INSTRUCTIONS

G13/GL13 LUMINAIRE TO ROUNDPOLE

IMPORTANT:

WARNING:

Read all instructions before performing any work. Be sure

prior to

installing luminaires.

Fixture must be grounded in accordance with appropriate codes. Failure to do so may

result in serious injury.

all power is off

NOTE: For installation other than a roundpole, follow the

instructions provided with the adaptor kit.

1. Place luminaire with lens facing up

on a non-scratching surface.

2. Unlatch door and slowly open until

stopped by safety cable. Remove
and retain wing nut that secures
safety cable. Disengage safety
cable from threaded stud and
pull free from ballast clamp.
Open door further until hinge
clamp lock is accessible. Rotate
hinge clamp lock to free hinge
clamp(Fig.1). Carefully rotate
door toward the closed position
until hinge disengages.

3. Place luminaire mounting surface

against round pole so that the
mounting holes align. With an
assistant holding the luminaire,
insert the bolster plate into the
inside of the pole. Secure the
luminaire using the 5/16” bolts
and lock washers supplied
(Fig.2). Tighten bolts to 15ft-lbs.