RC1xx LED Lighting Controllers - User Manual
—
37
—
Command
Example
Effect
RW
RW1,50
Set the unit to 50% switch mode.
RT
RT1,3,4,50
Set the unit to 3ms pulses, delayed by
4ms, at 50% brightness.
RE
RE1,6
Set the unit to ignore lighting errors and
make its trigger input active low.
TT
TT1,100
Set the internal trigger to operate every
100ms.
KB
KB1,23
Disable the keypad buttons on the front
panel. Set the unlock code to 23.
TR
TR1
Generate one trigger pulse.
ST
ST
Show the unit’s configuration details.
11
RC1xx reference information
This section of the user manual contains information about the RC1xx’s
specification, ratings. You can find further information in Section
11.2,
“Restrictions”, Section 11.3, “Event codes”, and Section 11.4, “Error codes”.
11.1
Specifications and ratings
RC100
RC120
User interface
Pushbutton
Ethernet and
Pushbutton
Output channel
One constant current output with SafeSense
Output current
Up to 1.0A continuous
and1.0A pulsed
Up to 1.2A continuous
and 2.0A pulsed
Output voltage
0V to 32V
Pulsed output
average power
25W maximum
Trigger input
Smart input compatible with 3V-24V, TTL, NPN, and
PNP. Input impedance 8kΩ nominal.
Pulse timing
From 100µs to 100ms in steps of 100µs.
Delay from
trigger to pulse
Maximum 10µs fixed latency plus user adjustable
steps of 100µs to a maximum of 100ms.