PP610/612 LED lighting controllers - User Manual
10.4
Pulsed mode output
These commands set the trigger source mode for pulsing, the pulse width
and delay.
Set the pulse parameters
RTfMmPpDd
Where:
f
output channel (1 or 2)
m
=
1 to trigger on input 1
2 to trigger on input 2
3 to trigger on either input
p
pulse width (in milliseconds)
d
delay before pulse (in milliseconds)
The
RT
command will not allow a delay to be set which is less than
the minimum for the current setting. When changing current and
delay values, it may be necessary to use the
RT
command to set the
delay to a higher value, then use the
RC
command (see
output current" on the next page
) to set the current,and then use the
RT
command again to set the delay to the required value.
The
RT
command can generate the following error codes:
Error
code
Description
44
Bad channel number
45
Channel number/trigger input mismatch
46
Invalid delay for programmed current
47
Invalid pulse width
—
43
—