PP600F/602F LED lighting controllers - User Manual
6
Mechanical fixing
The PP600F can be mounted onto a flat surface using the threaded holes
in the base, see the diagram below. The PP600F should only be mounted
either vertically or with its base horizontal. It should be mounted at least
15mm away from the sides of plastic enclosures. Likewise leave a similar
space between the PP600F and any parts which could be affected by high
temperatures.
Note:
The thickness of the base is 3.2mm. Fixing screws must not extend
into the enclosure by more than 6mm.
The enclosure of the PP600F is used to dissipate power in the form of heat.
For this reason the material to which the unit is attached must be suitable,
preferably metallic with ability to dissipate the produced heat. This is
particularly important if the power dissipation of the PP600F (as defined
by P
D
in
Section 10, Reference information
) exceeds 10 Watts.
The PP701 kit is available for mounting the PP600F on a DIN rail.
The PP600F does not have an IP rating and should be mounted so that
moisture and dirt cannot enter the unit.
To avoid a fire hazard, consider the implications of overheating in the
unlikely event of a fault in the PP600F. The power dissipation in a fault
—
15
—