Provide on the non-boarding and non-guide rail side of the platform a 

kick plate of not less 6 inches (150 mm) in height, measured vertically 

from the platform deck.

11.Controls:

a.

Controls: 24 VDC Low Voltage type.

b.

Platform equipped with emergency stop switch located within reach of 

passenger. Emergency stop button shall cause electric power to be 

removed from the drive system stopping lift immediately.

c.

Platform operating controls shall be two separate 1-1/2 inch (36 mm) 

diameter round illuminated constant pressure buttons with directional 

arrows, and an emergency stop switch mounted on the front surface of 

the platform control panel.

d.

When the platform arrives at landing and the user releases the 

directional control button, the user manually raises the arm on the entry 

side of the platform thus lowering the platform ramp.

e.

When the platform arrives at landing and the user releases the 

directional control button, the arm on the entry side of the platform is 

automatically raised and the corresponding platform ramp is 

simultaneously lowered (automatic platforms only).

f.

Platform control panel includes a receptacle for an optional plug-in 

attendant hand-held pendant control.

g.

Allow the platform to be called to the opposite landing in the folded 

position.

12.Attendant Hand-Held Pendant Control: Provide plug-in remote pendant control 

for attendant operation.

13.Platform on-Board Emergency Alarm: Provide platform with an on-board alarm 

that sounds when emergency stop button is pushed. The alarm shall have a 

battery back-up so that it will continue to function if lift power is lost.

B.

Drive and Guide Rail System:

1.Operation:

a.

Motor: 24 Volt PMDC motor with IP54 protection.

b.

Power requirements: 2 x12 VDC batteries located behind conveyance. 

Equipped with “out of charging station” alarm

c.

Charger: 120 VAC single phase, 50 Hz. On a dedicated circuit, 

providing 2 amp charging current to unit.

d.

Power Transmission: Worm gear reduction to a pinion moving on a 

fixed gear rack.

e.

Provide a frequency inverter to smoothly start and stop the platform 

motion.

f.

Locate drive carriage and associated control devices within the 

platform conveyance.

g.

Provide an upper final limit switch to stop the lift in the event of a failure 

of the primary limit switch.

h.

Equip drive system with an hour counter.

2.Guide Rail System:

a.

Two-part guide rail system consisting of:

1)

Main Upper Rail: Anodized aluminum extrusion weighing 8 lb/ft 

(11.9 kg/m) with integrally mounted zinc plated gear rack. 

2)

Lower Rail:  1-1/2 inches (38 mm) by 2-1/2 inches (64 mm) 

anodized aluminum extrusion.

b.

Rail Mounting:

1)

Direct Mount Solid Walls: Rails directly mounted to the stairway 

wall.

 

X3 Specification  23265-A-DS   Section 14 42 13    Page 5

Содержание X3

Страница 1: ...or lift attachment D Section 09260 Gypsum Board Assemblies Stair walls E Section 13650 Fire Alarm System Building Fire Alarm Integration system to connect the lift control system with the building fir...

Страница 2: ...g manufacturer s full range of available colors and patterns E Verification Samples For each finished product specified two samples representing actual product color and patterns PART 1 5QUALITY ASSUR...

Страница 3: ...l Free 800 663 6556 Tel 604 594 0422 Fax 604 594 9915 Email productinfo garaventalift com Web www garaventalift com B Substitutions Not permitted C Requests for substitutions will be considered in acc...

Страница 4: ...straining arms for passenger emergency evacuation e Top of arms mounted 37 3 8 inches 948 mm above platform deck When in guarding position arms are located above the perimeter of the platform f Gaps b...

Страница 5: ...folded position 12 Attendant Hand Held Pendant Control Provide plug in remote pendant control for attendant operation 13 Platform on Board Emergency Alarm Provide platform with an on board alarm that...

Страница 6: ...arding ramps and passenger safety arms 4 Provide Attendant remote control call station D Finish 1 Design and fabricate lift to manufacturer s standard design for indoor and outdoor locations a Aluminu...

Страница 7: ...ifts in accordance with in compliance with regulatory requirements specified and the manufacturer s instructions B Install system components and connect to building utilities C Accommodate equipment i...

Отзывы: