48.000in
1219.20mm
48.000IN
[1219.20mm]
48.000in
1219.20mm
FOR 4FT X8FT RACK
ONLY
FOR 4FT X8FT RACK
ONLY
REUSE THE DRILL TEMPLATE TO MARK MOUNTING HOLES ON THE CEILING
D
E
DETAIL D
SCALE 1 : 3
DETAIL E
SCALE 1 : 3
11/64"
[ 4.5mm]
2 3/8"
[60mm]
DRILL MARKED MOUNTING HOLES
(2) MOUNTING HOLES REQUIRED
PER CEILING BRACKET.
USE A MASONARY DRILL BIT
MARKED MOUNTING
HOLE WITH PENCIL
MOUNTING HOLE DIMENSIONS
CONCRETE CEILING
G
DETAIL G
SCALE 1 : 4
DRILLED
HOLE
ANCHOR
H
DETAIL H
SCALE 1 : 4
FIG. D2
J
DETAIL J
SCALE 1 : 4
CEILING
BRACKET
FIG. D3
K
DETAIL K
SCALE 1 : 4
DRILL
SUPPLIED
NUT DRIVER
FIG. D4
ANCHOR
STEP 1: 4FTX 4FT & 4FTX 8FT RACK-FOR CEILING BRACKET INSTALLATION
(SOLID CONCRETE CEILING)
WE PROVIDED WOOD SCREWS AND SOLID CONCRETE CEILING ANCHORS FOR THIS INSTALLATION.
PLEASE DETERMINE THE TYPE OF CEILING YOU HAVE BEFORE STARTING.
SOLID CONCRETE CEILING:
A: USE THE DRILL TEMPLATE TO MARK THE MOUNTING HOLES FOR INSTALLATION.
A1: START FROM THE LEFT, PLACE THE DRILL TEMPLATE AND MARK THE (2) HOLES.
A2: FROM THE (1) END MEASURE 48", PLACE THE DRILL TEMPLATE AND MARK THE NEXT SET OF (2) HOLES.
A3:
FOR 4FT X 8FT RACK ONLY,
MEASURE 48" OVER, PLACE THE DRILL TEMPLATE AND MARK THE NEXT SET OF (2) HOLES.
B: PILOT HOLES CONCRETE CEILING: USE A 15/32" (12 mm) DIA. MASONARY DRILL BIT AND DRILL A 2 3/8" (60mm)
DEEP HOLE FOR EACH ANCHOR.
C: INSERT (1) ANCHOR INTO EACH HOLE. USE A RUBBER MALLET TO TAP THE ANCHOR INTO THE CEILING.
D: FASTEN THE CEILING BRACKETS TO THE ANCHORS. USE A DRILL AND THE SUPPLIED NUT DRIVER.
SEE ANCHOR INSTRUCTIONS BELOW, FIG D1-D4.
FIG. D1
PAGE 6
KEEP EACH SET OF CEILING BRACKETS IN A STAIGHT LINE