2/3
1/2
LIMIT SWITCH
MANUAL LIMIT SETTING
NOTE: The manual limit setting allows the TOP or BOTTOM limit
to be set automatically by leaving the motor running and self-
stopping to the TOP end (cassette) or to the BOTTOM end.
1
Press and hold PROG-FC button until you
get a jog then release.
2
Press and hold the UP button for more
than 2 seconds then release.
The motor runs to the TOP limit.
2”
3
When you reach the TOP limit position
press STOP. The motor stops.
4
To set the TOP limit press STOP
again
.
The motor jogs. TOP limit is now set.