LIMIT SWITCH SETUP
(Just for motors with electronic limit switch)
ATTENTION: ALWAYS SET THE UP LIMIT FIRST
1
Push the LIMIT button until the motor makes a
brief jog.
Note: during “programming mode” the
operations are in “deadman control”
2
Press and hold the UP button and run the motor to
the desired UP limit position.
3
Press STOP to set the UP limit position. The motor
makes a brief jog.
4
Press and hold the DOWN button and run the
motor to the desired DOWN limit position.
5
Press STOP to set the DOWN limit position.
The motor makes a brief jog.
Note: accurate limit setting can be performed when UPWARD or DOWNWARD by pressing the
LIMIT button a second time. The motor then moves slowly in steps towards the desired limit.
Always press STOP button to set the limit position.
AUTOMATIC SETTING OF THE LIMITS
For limits set with torque sensor ( mechanical stop of shutters or cassette awnings/shades), press
and hold UP button until the bottom bar hits the cassette or shutter box.
A short jog will indicate that the UP position has been memorized. The same procedure can be
followed for DOWN limit but only for roller shutters.
LIMIT SWITCH