ZR-DH111NP
15
ALARM RECORD SETTING MENU
1 ALARM OPERATION
ON
Record when alarm occurs.
OFF
Do not record when alarm occurs.
2 RECORDING SPEED
The recording speed in alarm duration.
The max. recording speed is 2/3 (NTSC/PAL) HR.
The min. recording speed is 960 HR.
3 RECORDING QUALITY
Select the Recording picture quality when alarm
occurs.
LOWER
:
15 KB
LOW
:
20 KB
BASIC
:
25 KB
STANDARD
:
30 KB
HIGH
:
35 KB
SUPERIOR
:
40 KB
4 ALARM–IN TYPE
N.O.
Normal Open,
N.C.
Normal Close
5 ALARM–RESET TYPE
N.O.
Normal Open,
N.C.
Normal Close
6 ALARM DURATION TIME
Alarm holding time, alarm recording starts from
the beginning of alarm and stops at the end of
the duration.
The max. duration is NON - STOP, the min. dura-
tion is 10 Seconds.
7 PRE–ALARM OPERATION
ON
Record the picture in pre-alarm recording speed
in pre-alarm period.
OFF
No pre-alarm recording before alarm occurs.
Programming
ALARM RECORDING SETTING MENU
ALARM OPERATION
: ON
RECORDING SPEED
: 002 HR
RECORDING QUALITY
: STANDARD
ALARM — IN TYPE
: N.O.
ALARM — RESET TYPE
: N.O.
ALARM DURATION TIME
: 10 SECS
PRE-ALARM OPERATION
: ON
RECORDING SPEED
: 002 HR
8 RECORDING SPEED
The recording speed in pre-alarm period.
The max. recording speed is 2/3 (NTSC/PAL) HR.
The min. recording speed is 960 HR.
9 PRE–ALARM TIME
The duration of pre-alarm recording period. In 2/3
hour Real Time recording mode, the duration of
pre-alarm is about 5 seconds.
: Press LEFT or RIGHT to move
the cursor to the left or right.
: Press UP or DOWN or Jog Dial
to change the value.
Notice
If the alarm occurs when it is in standby mode or
in normal recording mode, the recording quality
will be the same as the normal recording quality.
If the alarm occurs when it is in timer recording
mode, the recording quality will be the same as
the value set in timer recording quality.
UP
LEFT
RIGHT
DOWN
Содержание ZR-DH111NP