ZA-NVE12K Hardware Manual
2010/2-1 E
16
4.3. Electrical characteristics
DC VOLTAGE
12V
RATED CURRENT
6.2A
CURRENT RANGE
0 ~ 6.8A
RATED POWER
74.4W
PEAK LOAD(10sec.)
Note.4
81.6W
RIPPLE & NOISE
(max.) Note.2
80mVp-p
VOLTAGE ADJ.
RANGE
3 ~3.5V
VOLTAGE
TOLERANCE Note.3
3.00%
LINE REGULATION
1.00%
LOAD REGULATION
3.00%
SETUP, RISE TIME
100ms, 35ms/230VAC 100ms,
35ms/115VAC at full load
Output
HOLD TIME (Typ.)
60ms/230VAC 12ms/115VAC at full load
VOLTAGE RANGE
90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY(Typ.) 80%
AC CURRENT (Typ.)
1.9A/115VAC 1.1A/230VAC
INRUSH CURRENT
(Typ.)
COLD START 18A/115VAC
36A/230VAC
Input
LEAKAGE CURRENT
<1mA / 240VAC
115 ~ 150% rated output power
OVER LOAD
Protection type : Hiccup mode, recovers
automatically after fault condition is
removed
13.8 ~ 16.2V
PROTECTION
OVER VOLTAGE
Protection type : Hiccup mode, recovers
automatically after fault condition is
removed
FUNCTION REMOTE
ON/OFF
RC+/RC- : 0 ~ 0.8V power on ; 4 ~ 10V
power of
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 Approved
WITHSTAND
VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
ISOLATION
RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M
Ohms/500VDC
EMI CONDUCTION &
RADIATION
Compliance to EN55011, EN55022
(CISPR22) Class B
SAFETY &
EMC
(Note 5)
HARMONIC
CURRENT
Compliance to EN61000-3-2,-3
Table 3. Electrical specification of PSU