![Gantner GAT Vending 6100 BA Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/gantner/gat-vending-6100-ba/gat-vending-6100-ba_installation-configuration-and-operation_3414648034.webp)
GAT Vending 6100 BA
Startup and Configuration
34
HB_GAT-VENDING6100BA--EN_121
www.gantner.com
User
Read
Option to read data from the user segment of the data
carrier and send to host
Boolean
false
Cash 1
Read
Option to read data from the first cash segment of the
data carrier and send to host
Boolean
False
Cash 2
Read
Option to read data from the second cash segment of
the data carrier and send to host
Boolean
False
Access
Read
Option to read data from the access segment of the
data carrier and send to host
Boolean
False
Third party
Read
Option to read data from the third party segment of the
data carrier and send to host
Boolean
False
Timeouts
Ident timeout
Timeout in milliseconds for input after a data carrier is
identified (read)
Integer
30000
Product draw timeout
Timeout in milliseconds for feedback from vending
machine after product selection
Integer
60000
Idle timeout
Timeout in milliseconds for product selection
Integer
15000
Feedback screen
Timeout in milliseconds for all feedback screens
Integer
3000
Cashless Device
Mainly for service technicians.
Default currency code
Define the default currency code
Integer
Country code
Define the country code
Integer
Scale factor
Define the scale factor for cash values
Integer
Decimal places
Define the number of decimal places for cash values
Integer
2
Force single vend
Option to cancel vending session after each
transaction. Required for vending machines that start
multiple vending transactions
Boolean
False
Use VMC display
Option to show GAT Vending 6100 BA text on the
vending machine’s display (where possible)
Boolean
False
Online request
Option to perform an online request for every product.
The host can individually allow special products or
send online prices
Boolean
False
MDB address
Select the cashless device number in use at the
vending machine. “Cashless Device 1” or Cashless
Device 2”
Menu
Cashless
Device 1
Verify age
Option to activate age checking functionality, as far as
the information is available
Boolean
False
Check card available
Option to end vending session when data carrier is
removed from the RFID reading field
Boolean
False
Auto reset timeout
Reset MDB bus after terminal is set to inactive mode
for x seconds. 0 = disable auto reset function
Integer
Bus Timeout Factor
Factor to increase the timeout for MDB communication
for slow answers (1 = 5 ms, 2 = 10 ms, 3 = 15 ms, 4 =
20 ms, 5 = 25 ms)
Integer
VMC Status
Read-only data. Mainly for service technicians. VMC = Vending Machine Controller
VMC connection
VMC connection
VMC feature level
VMC feature level
VMC feature bits
VMC feature bits
VMC manufacturer
VMC manufacturer
VMC serial number
VMC serial number
VMC model number
VMC model number
VMC SW version