GAT NET.Lock 7020 System
Technical Data
www.gantner.com
HB_GAT-NETLOCK7020--EN_12
59
7.
TECHNICAL DATA
7.1
GAT NET.Lock 7020
Nominal voltage
- GAT NET.Lock 7020 (P):
DC 5 V
- GAT NET.Lock 7020 USB (P):
DC 24 V
Power supply:
Via connection cable from sub controller
Average power consumption
- GAT NET.Lock 7020 (P):
60 mW
- GAT NET.Lock 7020 USB (P):
65 mW (without USB charging, without LED)
Charging current
(GAT NET.Lock 7020 USB (P))
Up to 2 A per lock and max. 70 W per controller*
* When multiple devices are being charged simultaneously at multiple locks of a sub
controller, the charging current of the sub controller is automatically distributed
between these locks.
Max. transmission power:
<400 mW
RFID frequency
- GAT NET.Lock 7020 (USB):
13.56 MHz
- GAT NET.Lock 7020 (USB) P:
13.56 MHz + 125 kHz
Break-in resistance capability:
DIN 4547-2 class C
Signaling element:
Multi-color status LED
Interface to sub controller:
One-wire (special cable for supply, data, and RF signal)
Connectors:
MOLEX, type Micro-
Fit 3.0™
Housing material:
Plastic (PC)
Door width:
Min. 230 mm (9.05 in)
Dimensions
- GAT NET.Lock 7020 (P):
110 x 100 x 25 mm (4.33 x 3.94 x 0.98 in)
- GAT NET.Lock 7020 USB (P):
110 x 100 x 37 mm (4.33 x 3.94 x 1.46 in)
Weight:
Approx. 160 g (5.6 oz)
Permitted ambient temperature:
0 °C to +60 °C (32 °F to 140 °F)
Protection type:
IP 52
Protection class:
III
Environment class based on VdS 2110:
II (conditions in indoor areas)
Compliance:
CE, FCC, IC, ETL