GAT Access 6100 Terminal Series
Technical Data
www.gantner.com
HB_GAT-ACCESS6100--EN_14
93
9
TECHNICAL DATA
9.1
Power Supply
Nominal voltage
- GAT Access 6100 / F BIO / Enrollment Station:
- GAT Access 6100 F PoE:
DC 12 / 24 V (SELV - Safety Extra-Low Voltage)
DC 48 V (SELV - Safety Extra-Low Voltage)
Permitted input voltage
- GAT Access 6100 / F BIO / Enrollment Station:
- GAT Access 6100 F PoE:
DC 10 - 28 V
DC 36 - 57 V
Power supply:
Only with LPS (Limited Power Source) power supply
Average power consumption
- GAT Access 6100:
- GAT Access 6100 F BIO / Enrollment Station:
- GAT Access 6100 F PoE:
3 W
Full operation with sensor on: 4.5 W
Full operation with sensor off: 3.5 W
Power class 3
9.2
Reader
Reader types
- GAT Access 6100 B:
- GAT Access 6100 BA:
- GAT Access 6100 ISO:
- GAT Access 6100 F:
- GAT Access 6100 F PoE:
- GAT Access 6100 F BIO:
- GAT Access 6100 F Enrollment Station:
LEGIC prime
LEGIC advant
ISO 15693
MIFARE
MIFARE
MIFARE
MIFARE
Max. transmission power:
200 mW
Frequency of reading field:
13.56 MHz
9.3
Interface & Connections
Host interface:
Ethernet 10/100 Mbit/s
Connection terminals:
0.5 to 1.5 mm2
Содержание GAT Access 6100 Series
Страница 10: ...GAT Access 6100 Terminal Series Table of Contents 10 HB_GAT ACCESS6100 EN_14 www gantner com...
Страница 18: ...GAT Access 6100 Terminal Series General Information 18 HB_GAT ACCESS6100 EN_14 www gantner com...
Страница 34: ...GAT Access 6100 Terminal Series Installation 34 HB_GAT ACCESS6100 EN_14 www gantner com...
Страница 42: ...GAT Access 6100 Terminal Series Electrical Connections 42 HB_GAT ACCESS6100 EN_14 www gantner com...
Страница 80: ...GAT Access 6100 Terminal Series Operation 80 HB_GAT ACCESS6100 EN_14 www gantner com...
Страница 84: ...GAT Access 6100 Terminal Series Updating the GAT Access 6100 84 HB_GAT ACCESS6100 EN_14 www gantner com...
Страница 92: ...GAT Access 6100 Terminal Series Troubleshooting FAQ 92 HB_GAT ACCESS6100 EN_14 www gantner com...