16
pieces
showing
1000
and
the
output
data
is
WT□□□12.345□kg↓UW□□12.34□g↓QT□□1000□Pcs↓←41 bits
。
To display accumulation
MW□□12345.6□kg↓ 15 bits
MN□□□12□□□□↓ 12 bits
MQ□12345□Pcs↓← 14 bits
8.3 Receive order
:
need to receive the communication, then receive
order.
When the communication setting is 27(default statue), in other
words Hexadecimal system 1BH, the orders to scale are:
1BH+70H(ACS
Ⅱ
code p): print
(
scale required to send date once
)
;
1BH+71H(ACS
Ⅱ
code q): calibration;
1BH+72H(ACS
Ⅱ
code r): count;
1BH+73H(ACS
Ⅱ
code s): unit conversion;
1BH+74H(ACS
Ⅱ
code t): tare;
1BH+75H(ACS
Ⅱ
code u): backlight;
8.4 RS232C output pins content (DB9 socket): 2 pins: RXD; 3 pins:
TXD; 5pins: GND. With computer RS232C socket (DB9 socket)
connected:
2 —— 3
3 —— 2
5 —— 5