Chapter 1: Safety Considerations - Inspection 

1 - 1 

Chapter 1: Safety Considerations 

Your Faraday 

Shield has been supplied in a safe condition. This chapter of the Operator’s Manual contains some 

information and warnings that you must follow to insure continued safe operation.  

Inspection 

When you receive your Faraday Shield, inspect it for evidence of shipping damage. If any damage is noted, please 
notify Gamry Instruments Inc. and the shipping carrier immediately. Save the shipping container for possible 
inspection by the carrier. 

Grounding in the Faraday Shield  

The metal case of the Faraday Shield is 

not

 connected to an earth ground. Grounding is best accomplished by 

connecting the ground lead of the potentiostat to the internal ground lug of the Faraday Shield. Proper grounding 
is required for the Faraday cage to function.  

Most electrochemical cells are isolated from earth ground, in which cases isolation of the Faraday Shield from 
earth is not required. Connection of the Faraday Shield to an earth ground (when allowed) may lower the noise 
seen in an electrochemical test. 

 

This connection of the Faraday Shield to an earth ground i

s not a “Protective

 

Earth Ground” as defined in IEC 1010. 

The Faraday Shield is safe in the absence of this connection, for it does not contain any hazardous voltages.  

 

Temperature and ventilation 

Your Faraday Shield was designed for indoor use at ambient temperatures between 0

C and 45

C. You may need 

to ventilate or even cool the Faraday Shield with forced air if the temperature rises excessively.  

 

Sources of earth ground include: 

• 

most metal water pipes 

• 

the chassis of most electronic apparatus (which are generally earth grounded) 

• 

the protective ground terminal of an AC mains power plug 

We recommend that you discuss grounding with an electrical or electronics professional 
prior to making this earth ground connection. 

 

 

Warning! Do not connect the Faraday Shield

’s ground binding post to any voltage other 

than a potentiostat’s floating or earth ground. An improper connection can create a safety 

hazard, which could result in personal injury or death. 

 

Содержание Faraday Shield

Страница 1: ...Faraday Shield Operator s Manual...

Страница 2: ......

Страница 3: ...dard Time 877 367 4267 Toll Free US Canada Only We will be happy to provide a reasonable level of free support for registered users Reasonable support includes telephone assistance covering the normal...

Страница 4: ...any obligation to install same on systems previously purchased All system specifications are subject to change without notice There are no warranties which extend beyond the description herein This wa...

Страница 5: ...hecked and is believed to be accurate as of the time of printing However Gamry Instruments Inc assumes no responsibility for errors that might appear Copyrights Faraday Shield Operator s Manual copyri...

Страница 6: ...iv...

Страница 7: ...ature and ventilation 1 1 Environmental limits 1 2 Use with dangerous materials 1 2 Cleaning 1 2 Leakage inside 1 2 RoHS Compliance 1 3 Chapter 2 Introduction 2 1 About this manual 2 1 About the Farad...

Страница 8: ...Copyrights Inspection...

Страница 9: ...is not required Connection of the Faraday Shield to an earth ground when allowed may lower the noise seen in an electrochemical test This connection of the Faraday Shield to an earth ground is not a...

Страница 10: ...tively you can use isopropyl alcohol Do not use a wet rag or allow fluid to enter the enclosure Do not immerse the Faraday Shield in any type of cleaning fluid including water Do not use any abrasive...

Страница 11: ...Chapter 1 Safety Considerations RoHS Compliance 1 3 RoHS Compliance The Faraday Shield has been built using lead free components This equipment complies with the European RoHS initiative...

Страница 12: ...om earth ground Adjustable plastic shelf for reducing capacitive effects Ring stand rod for mounting clamps various connectors or adapters to hold glassware cables or any other laboratory equipment No...

Страница 13: ...Chapter 3 Unpacking and Installation Notational conventions 3 1 Chapter 3 Unpacking and Installation Front view of an open Faraday Shield...

Страница 14: ...14 Top Panel Sub assembly 1 988 00078 Operator s Manual All panel sub assemblies have their cable entry plates P N 810 00123 already pre mounted Initial visual inspection After you remove your Faraday...

Страница 15: ...bly to one side panel using the quick release hinges open the door and slightly lift up the front part of the bottom panel with its standoffs align front panel and connect other side using the quick r...

Страница 16: ...g and Installation Assembly 3 4 5 Mount top panel sub assembly put top panel sub assembly on top side of cage use four thumb screws to attach 6 Interconnect side panels use four thumbs screws to conne...

Страница 17: ...e panels at two different heights o place shelf on flanges upper or lower level and attach with six thumb screws o slightly open thumb screws and slide shelf to remove it 8 Adjust cable entry plates f...

Страница 18: ...eld within an enclosed space make sure that the internal temperature within that space does not exceed the 45 C ambient temperature limit of the Faraday Shield Be particularly careful if a computer or...

Страница 19: ...Chapter 3 Unpacking and Installation Physical location 3 7 Faraday Shield fully assembled The Faraday Shield is not designed for outdoor use...

Страница 20: ...inch length 35 cm 13 7 inch height 41 7 cm 16 4 inch Door opening max width 28 8 cm 11 3 inch height 40 5 cm 16 inch Top opening max width 30 2 cm 11 8 inch length 30 2 cm 11 8 inch Cable opening max...

Страница 21: ...Appendix A Specifications Physical location 3 9...

Страница 22: ...tions notational 2 1 earth ground 1 1 environmental limits 1 2 inspection 1 1 leaks 1 2 operation 1 2 physical location 3 6 safety 1 1 service contract i shipping 1 2 shipping damage 1 1 specification...

Отзывы: